LP4K0910BW3
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides a low...
£ 35.26 - £ 60.41 Excl. VAT
Loyalty points:
21
LP1K0901BD
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 24 V DC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive...
£ 25.65 - £ 43.93 Excl. VAT
Loyalty points:
16
LP1K0910BD
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive...
£ 25.65 - £ 43.93 Excl. VAT
Loyalty points:
16
LP1K0601BD
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 24V DC...
£ 24.85 - £ 42.58 Excl. VAT
Loyalty points:
15
LUB32
Power base, TeSys U, 3P, 32A/690V
TeSys U standard power base, 3 poles (3NO), 32A/690V, to be completed with a control unit LUC to form a TeSys U...
£ 63.67 - £ 109.07 Excl. VAT
Loyalty points:
40
GV1L3
Current limiter module, TeSys GV2, on device mounting
TeSys GV short circuit current limiter block for motor circuit breakers GV2L/LE/P/ME/RT. It increases the ability of the...
£ 48.23 - £ 77.39 Excl. VAT
Loyalty points:
29
LRD07
TeSys LRD thermal overload relays - 1.6...2.5 A - class 10A
TeSys LRD thermal overload relay, 2.5A/690V, thermal setting range 1.6-2.5A, tripping class 10A, for protection of...
£ 32.06 - £ 51.45 Excl. VAT
Loyalty points:
21
LRD10
TeSys LRD thermal overload relays - 4...6 A - class 10A
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase...
£ 32.06 - £ 51.45 Excl. VAT
Loyalty points:
21
LRD04
TeSys LRD thermal overload relays - 0.4...0.63 A - class 10A
TeSys LRD thermal overload relay, 0.63A/690V, thermal setting range 0.4-0.63A, tripping class 10A, for protection of...
£ 32.06 - £ 51.45 Excl. VAT
Loyalty points:
21
LRD05
TeSys LRD thermal overload relays - 0.63...1 A - class 10A
TeSys LRD thermal overload relay, 1A/690V, thermal setting range 0.63-1A, tripping class 10A, for protection of...
£ 32.06 - £ 51.45 Excl. VAT
Loyalty points:
21
LRD03
TeSys LRD thermal overload relays - 0.25...0.4 A - class 10A
TeSys LRD thermal overload relay, 0.4A/690V, thermal setting range 0.25-0.4A, tripping class 10A, for protection of...
£ 32.06 - £ 51.45 Excl. VAT
Loyalty points:
21
LR2K0312
TeSys K - differential thermal overload relays - 3.7...5.5 A - class 10A
TeSys LRK thermal overload relay, 5.5A/690V, thermal setting range 3.7-5.5A, tripping class 10A, for protection of...
£ 27.25 - £ 46.69 Excl. VAT
Loyalty points:
17
LR2K0310
TeSys K - differential thermal overload relays -2.6...3.7 A - class 10A
TeSys LRK thermal overload relay, 3.7A/690V, thermal setting range 2.6-3.7A, tripping class 10A, for protection of...
£ 27.25 - £ 46.69 Excl. VAT
Loyalty points:
17
LR2K0305
TeSys K - differential thermal overload relays - 0.54...0.8 A - class 10A
TeSys LRK thermal overload relay, 0.8A/690V, thermal setting range 0.54-0.8A, tripping class 10A, for protection of...
£ 27.25 - £ 46.69 Excl. VAT
Loyalty points:
17
VZ31
TeSys VARIO - shaft extension - for V3 / V4 / V5 / V6
TeSys Vario shaft extension, for TeSys Vario switch bodiesV3 to V6. It allows the operation of a switch body located...
£ 13.07 - £ 22.40 Excl. VAT
Loyalty points:
8
VCF0GE
TeSys Vario enclosed, emergency switch disconnector, 20A, IP65
TeSys enclosed starter with switch disconnector, 3 poles, Ithe 20A 690V, for main and emergency stop switching in...
£ 35.94 - £ 61.56 Excl. VAT
Loyalty points:
21
VCCF3
TeSys Vario - emergency stop switch disconnector - 63 A - back of enclosure
TeSys Vario switch disconnector for mounting at back of an enclosure, 3 poles, 63A/690V, for motor switching...
£ 70.25 - £ 120.35 Excl. VAT
Loyalty points:
42
VZ10
TeSys Mini-VARIO and VARIO - terminal shrouds - for V5 / V6
TeSys Vario 3-pole terminal protection shroud, for TeSys Vario switch-disconnectors. To be used with V5 and V6 switch...
£ 3.69 - £ 6.31 Excl. VAT
Loyalty points:
2
VZ11
TeSys VARIO - additional neutral block - 40 A - for V02...V2
TeSys Vario add-on module, neutral pole 12-40A 690V, for TeSys Vario switch-disconnector. To be used with V02 to V2...
£ 12.25 - £ 20.98 Excl. VAT
Loyalty points:
7
DF101
Fuse carrier TeSys DF, 1P 32A, fuse size 10 x 38 mm
TeSys DF modular fuse carrier, 1 pole (1P), for protection of control circuits up to 32A/690V. To be used with 10x38mm...
£ 4.50 - £ 7.70 Excl. VAT
Loyalty points:
3
LC1K1210B7
TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NO aux. - 24 V AC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive...
£ 24.05 - £ 41.20 Excl. VAT
Loyalty points:
14
LC1K0910B7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V AC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive...
£ 20.84 - £ 35.70 Excl. VAT
Loyalty points:
13
LC1K0910F7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 110 V AC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive...
£ 20.84 - £ 35.70 Excl. VAT
Loyalty points:
13
LC1D09BD
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V DC coil
TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a 24V...
£ 51.14 - £ 82.04 Excl. VAT