Modicon TM3 Safety module - 3 Function, Cat 4 PL e/SIL CL3 (spring) 24Vdc

Modicon TM3 Safety module - 3 Function, Cat 4 PL e/SIL CL3 (spring) 24Vdc

This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has spring terminals for fast and reliable wiring of safety circuits.

Product identifiers

SKU: TM3SAK6RG
EAN: 3606485393049
GTIN: 3606485393049
MPN: TM3SAK6RG

V+ Loyalty points:

122

Price: £ 244.00 Excl. VAT


Categories

Features

Depth
73 mm
Model
Other
Width
43.7 mm
Height
94 mm
EFDE0031
no
Release-delay
With start input
no
Control voltage 1
Control voltage 2
Evaluation inputs
Other
Power consumption
1.1 W
Supply voltage DC
Operating voltage DC
Rated switch current
1.1 A
With muting function
no
With feedback circuit
no
With detachable clamps
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
With approval for BG BIA
no
Type of control voltage 1
DC
Type of control voltage 2
DC
Operating voltage AC 50 Hz
Operating voltage AC 60 Hz
SIL according to IEC 61508
None
Suitable for rail mounting
no
Type of electric connection
Other
Voltage type (supply voltage)
DC
With approval according to UL
no
Voltage type (operating voltage)
DC
Suitable for monitoring of valves
no
Stop category according to IEC 60204
Other
Type of safety according to IEC 61496-1
1
Suitable for monitoring of tactile sensors
no
Suitable for monitoring of magnetic switches
no
Suitable for monitoring of position switches
no
Performance level according to EN ISO 13849-1
None
Suitable for monitoring of proximity switches
no
Suitable for monitoring of emergency-stop circuits
no
Number of outputs, safety related, delayed, with contact
-
Number of outputs, safety related, delayed, semiconductors
-
Number of outputs, safety related, undelayed, with contact
-
Number of outputs, safety related, undelayed, semiconductors
-
Number of outputs, signalling function, delayed, with contact
-
Suitable for monitoring of optoelectronic protection equipment
no
Number of outputs, signalling function, delayed, semiconductors
-
Number of outputs, signalling function, undelayed, with contact
-
Number of outputs, signalling function, undelayed, semiconductors
-