Modicon TM3 Safety module - 1 Function, Cat 4 PL e/SIL CL3 (spring) 24Vdc
This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
Product identifiers
SKU: TM3SAF5RG
EAN: 3606485393001
GTIN: 3606485393001
MPN: TM3SAF5RG
Loyalty points:
109
Price range: £ 268.38 - £ 275.13 Excl. VAT
Categories
Features
|
Depth
|
73 mm
|
|
Model
|
Other
|
|
Width
|
43.7 mm
|
|
Height
|
94 mm
|
|
EFDE0031
|
TRUE
|
|
Release-delay
|
|
|
With start input
|
FALSE
|
|
Control voltage 1
|
|
|
Control voltage 2
|
|
|
Evaluation inputs
|
Other
|
|
Power consumption
|
1.1 W
|
|
Supply voltage DC
|
|
|
Operating voltage DC
|
|
|
Rated switch current
|
1.1 A
|
|
With muting function
|
FALSE
|
|
With feedback circuit
|
FALSE
|
|
With detachable clamps
|
FALSE
|
|
Supply voltage AC 50 Hz
|
|
|
Supply voltage AC 60 Hz
|
|
|
With approval for BG BIA
|
FALSE
|
|
Type of control voltage 1
|
DC
|
|
Type of control voltage 2
|
DC
|
|
Operating voltage AC 50 Hz
|
|
|
Operating voltage AC 60 Hz
|
|
|
SIL according to IEC 61508
|
3
|
|
Suitable for rail mounting
|
TRUE
|
|
Type of electric connection
|
Spring clamp connection
|
|
Voltage type (supply voltage)
|
DC
|
|
With approval according to UL
|
TRUE
|
|
Voltage type (operating voltage)
|
DC
|
|
Suitable for monitoring of valves
|
FALSE
|
|
Stop category according to IEC 60204
|
1
|
|
Type of safety according to IEC 61496-1
|
None
|
|
Suitable for monitoring of tactile sensors
|
FALSE
|
|
Suitable for monitoring of magnetic switches
|
FALSE
|
|
Suitable for monitoring of position switches
|
FALSE
|
|
Performance level according to EN ISO 13849-1
|
Level e
|
|
Suitable for monitoring of proximity switches
|
FALSE
|
|
Suitable for monitoring of emergency-stop circuits
|
TRUE
|
|
Number of outputs, safety related, delayed, with contact
|
-
|
|
Number of outputs, safety related, delayed, semiconductors
|
-
|
|
Number of outputs, safety related, undelayed, with contact
|
3
|
|
Number of outputs, safety related, undelayed, semiconductors
|
-
|
|
Number of outputs, signalling function, delayed, with contact
|
-
|
|
Suitable for monitoring of optoelectronic protection equipment
|
FALSE
|
|
Number of outputs, signalling function, delayed, semiconductors
|
-
|
|
Number of outputs, signalling function, undelayed, with contact
|
-
|
|
Number of outputs, signalling function, undelayed, semiconductors
|
-
|