OKA25S3G EMC Encl. Switch Disconnector
3x rewards on ABB switch fuses & switches at TLA!
EMC Encl. Switch Disconnector, 3-p. 415V AC23 20A, 11kW. Aluminium enclosure. IP65. Black Round handle. Interlocked cover. The dye casted aluminum alloy (silumin) enclosure is extremely rigid, and well suited for harsh environment. The surface is polyester coated and well protected from corrosion. Installation is made easy, thanks to the easy access to terminals, screwed cover and with the compression cable glands included. The cover is interlocked, and handle padlockable with two padlocks. The handle can also be padlocked in On position, by removing two small plastic bits. The enclosure is EMC type, when EMC glands (not included) are used. N and PE terminals are included.
Product identifiers
SKU: 1SCA142685R1001
EAN: 6417019701844
GTIN: 6417019701844
MPN: OKA25S3G
Loyalty points:
339 (113x3)
Price: £ 226.25 Excl. VAT
Categories
Features
|
Depth
|
103
|
|
Width
|
130
|
|
Height
|
165
|
|
Interlockable
|
yes
|
|
Number of poles
|
3
|
|
Number of switches
|
1
|
|
Device construction
|
Complete device in housing
|
|
Motor drive optional
|
no
|
|
Colour control element
|
Black
|
|
Motor drive integrated
|
no
|
|
Version as main switch
|
yes
|
|
Rated operating voltage
|
|
|
Type of control element
|
Turn button
|
|
Switching power at 400 V
|
11
|
|
Version as safety switch
|
no
|
|
Voltage release optional
|
no
|
|
Rated permanent current Iu
|
32
|
|
With pre-assembled cabling
|
-
|
|
Degree of protection (NEMA)
|
Other
|
|
Suitable for floor mounting
|
-
|
|
Version as reversing switch
|
no
|
|
Max. rated operation voltage Ue AC
|
750
|
|
Suitable for front mounting 4-hole
|
no
|
|
Suitable for front mounting centre
|
no
|
|
Suitable for intermediate mounting
|
-
|
|
Width in number of modular spacings
|
-
|
|
Rated operation power at AC-3, 400 V
|
-
|
|
Degree of protection (IP), front side
|
IP65
|
|
Rated operation power at AC-23, 400 V
|
11
|
|
Rated short-time withstand current lcw
|
1
|
|
Version as emergency stop installation
|
no
|
|
Version as maintenance-/service switch
|
yes
|
|
Rated permanent current at AC-21, 400 V
|
-
|
|
Rated permanent current at AC-23, 400 V
|
20
|
|
Conditioned rated short-circuit current Iq
|
-
|
|
Suitable for distribution board installation
|
yes
|
|
Type of electrical connection of main circuit
|
Screw connection
|
|
Number of auxiliary contacts as change-over contact
|
0
|
|
Number of auxiliary contacts as normally open contact
|
0
|
|
Number of auxiliary contacts as normally closed contact
|
0
|