Flat cable Eca 3G 2.5 mm² light gray

Flat cable Eca 3G 2.5 mm² light gray

Flat cable; Eca; 3G 2.5 mm²; PVC; L + PE + N; 0.6/1 kV; 2,50 mm²; light gray

Product identifiers

SKU: 897-231
EAN: 4045454004170
GTIN: 4045454004170
MPN: 897-231

Price: £ 0.00 Excl. VAT


Categories

Features

Screen
-
Weight
185
AWG size
-
Drain wire
-
Cable geometry
Flat
Number of cores
3
Strand diameter
-
Conductor surface
Tinned
Nominal voltage U
1000
Stranding element
No
Torsion resistant
-
Conductor category
Class 5 = flexible
Conductor material
Copper
Material armouring
-
Nominal voltage U0
600
Protective barrier
-
Shape of conductor
Round
Suspension element
None
Cable width approx.
16.9
Colour outer sheath
Other
Core identification
Colour
Cable height approx.
6.5
Material outer sheath
Polyvinyl chloride (PVC)
Screen over stranding
None
Outer diameter approx.
-
Armouring/reinforcement
-
Material core insulation
-
With protective conductor
yes
Max. conductor temperature
-
Number of stranding elements
-
Screen over stranding element
None
Specification core insulation
-
Conductor resistance at 20 °C
8.21
Nominal cross section conductor
2.5
Number of strands per conductor
-
Number of pilot/reduced conductors
-
Specification material outer sheath
-
Low smoke according to EN IEC 61034-2
-
Nominal cross section conductor (AWG)
-
Halogen free according to EN IEC 60754-1
no
Halogen free according to EN IEC 60754-2
no
Halogen free according to EN IEC 60754-3
no
Max. tensile strength during installation
-
Core identification according to HD 308 S2
-
Flame retardant according to IEC 60332-1-2
-
Oil resistant according to EN IEC 60811-404
no
Nominal cross section pilot/reduced conductors
-
Reaction-to-fire according to EN 13501-6: Class
Eca
Reaction-to-fire according to EN 13501-6: Acidity
-
Flame retardant according to IEC 60332-3-22 (Cat A)
-
Flame retardant according to IEC 60332-3-23 (Cat B)
-
Flame retardant according to IEC 60332-3-24 (Cat C)
-
Flame retardant according to IEC 60332-3-25 (Cat D)
-
Nominal cross section pilot/reduced conductors (AWG)
-
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
-
Reaction-to-fire according to EN 13501-6: Smoke production
-
Low temperature resistant according to EN 60811-504+505+506
-
Permitted cable outer temperature during assembling/handling
Min. permitted bending radius, moving application/free movement
-
Permitted cable outer temperature after assembling without vibration
-25 - 70
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
-
Min. permitted bending radius, moving application with forced guidance
-
Min. permitted bending radius, stationary application/permanent installation
36

Downloads