This product is part of Smart Relay - Zelio Logic SR2/SR3, an offer of simple automation systems from 10 to 40 I/Os. This Zelio Logic compact smart relay features 20 I/Os, local display, 0 to 240 with ladder and 0 to 500 with FBD programming control scheme lines. It is a module with rated supply voltage of 12V DC and cycle time of 6ms to 90ms. It offers 12 resistive discrete inputs with voltage of 12V DC, 6 analogue input ranges from 0V to 10V, 0V to 12V and 8 relay outputs. It is an IP20 and IP40 rated product. It weighs 0.38kg. The main application of this module is industry and building/service sector. This product is certified by C-Tick, GL, UL, CSA and GOST. It meets EN/IEC 60068-2-6 Fc and EN/IEC 61000-4-11 standards. Easy to use, Zelio Logic provides a real alternative solutions based on cabled logic or specific cards.

Product identifiers

SKU: SR2B201JD
EAN: 3389110549720
GTIN: 3389110549720
MPN: SR2B201JD

Voltimum+ Loyalty Programme Loyalty points: 1

Price: £ 253.86 Excl. VAT

Specifications

Depth 59.5 mm
Width 124.6 mm
Height 90 mm
Expandable no
Redundancy no
Basic device yes
With display yes
IO link master no
Power consumption 2.5 W
Switching current 8 A
Radio standard GSM no
Radio standard UMTS no
With optical interface no
Front built-in possible yes
Supply voltage AC 60 Hz
Radio standard Bluetooth no
Number of analogue inputs 6
Number of analogue outputs 0
SIL according to IEC 61508 None
Number of HW-interfaces USB 0
Supporting protocol for CAN no
Supporting protocol for LON no
Number of interfaces PROFINET 0
Voltage type (supply voltage) DC
Number of HW-interfaces RS-232 1
Number of HW-interfaces RS-485 0
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for PROFIsafe no
Number of HW-interfaces serial TTY 0
Supporting protocol for PROFINET IO no
Supporting protocol for Data-Highway no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems no
Number of HW-interfaces industrial Ethernet 0
Certified for UL hazardous location class II no
Performance level according to EN ISO 13849-1 None
Certified for UL hazardous location division 2 no
Certified for UL hazardous location group D (propane) no
Certified for UL hazardous location group C (ethylene) no
Certified for UL hazardous location group E (metal dusts) no
Certified for UL hazardous location group G (non-conductive dusts) no