Distributed analog/discrete I/O Modicon Momentum

Distributed analog/discrete I/O Modicon Momentum

This I/O module is part of the Modicon Momentum range, an offer of controller and IP20 monoblock I/Os for distributed control architecture. This distributed analog, discrete I/O base module offers 8 discrete outputs, 8 discrete inputs, 6 analog inputs and 4 analog outputs. It is a module with analog input/output voltage ranges from 0V to 10V and discrete input voltage of 24V DC and discrete output voltage from 10V to 30V. There is an isolation between analog I/O and operating voltage, operating voltage and I/O from the ground at 500V. It is furnished with 2 removable terminal blocks for electrical connection. It features 4 LEDs for channel status signaling. Its dimensions are 141.5mm (width) x 47.5mm (depth) x 125mm (height). It weighs 0.24kg. The main application of this module is infrastructures and energy, material handling, simple machine control. This product is certified by CE, CSA and UL. It is suitable for wall mount. Momentum is a flexible, modular family of components that easily snaps together and can be configured for a wide range of distributed I/O and control applications. System with 4 fundamental components that easily snap together in various combinations to form versatile control systems or sub-systems.

Product identifiers

SKU: 170ANR12090
EAN: 3595860019523
GTIN: 3595860019523
MPN: 170ANR12090

V+ Loyalty points:

576

Price: £ 1,151.00 Excl. VAT


Categories

Features

Depth
47.5 mm
Width
141.5 mm
Height
125 mm
IO link master
no
System accessory
yes
Supply voltage DC
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
no
Type of digital output
Transistor
Type of output voltage
AC/DC
With optical interface
no
Analogue input, current
no
Analogue input, voltage
yes
Front built-in possible
yes
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Analogue input, resistor
no
Analogue output, current
no
Analogue output, voltage
yes
Number of digital inputs
8
Radio standard Bluetooth
no
Degree of protection (IP)
Other
Input current at signal 1
6 mA
Number of analogue inputs
6
Number of digital outputs
8
Number of analogue outputs
4
Permitted voltage at input
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
yes
Digital inputs configurable
yes
Number of HW-interfaces USB
0
Supporting protocol for ASI
no
Supporting protocol for CAN
no
Supporting protocol for KNX
no
Supporting protocol for LON
no
Time delay at signal change
Type of electric connection
Flat plug-in connection
Analogue input, thermocouple
no
Analogue inputs configurable
yes
Digital outputs configurable
yes
Analogue outputs configurable
yes
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
AC/DC
Wall mounting/direct mounting
yes
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Type of voltage (input voltage)
AC/DC
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Output current at digital output
0.25 A
Output voltage at digital output
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
None
Resolution of the analogue inputs
14 Bit
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Analogue input signal configurable
yes
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Resolution of the analogue outputs
14 Bit
Analogue output signal configurable
yes
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Analogue input, resistor temperature
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
no
Performance level according to EN ISO 13849-1
None
Short-circuit protection, digital outputs available
yes
Supporting protocol for AS-Interface Safety at Work
no
Fieldbus connection over separate bus coupler possible
no