Discrete I/O extension module - 14 I O - 12 V DC - for Zelio Logic

Discrete I/O extension module - 14 I O - 12 V DC - for Zelio Logic

This product is part of Smart Relay Zelio Logic SR2/SR3, an offer of simple automation systems from 10 to 40 I/Os. This discrete I/O extension module features 14 I/Os and 120 with ladder programming control scheme lines. It is a module with rated supply voltage of 12V DC and cycle time of 6ms to 90ms. It offers 8 resistive discrete inputs with voltage of 12V DC and 6 relay outputs with voltage ranges from 24V to 250V AC and 5V to 30V DC. It is an IP20 and IP40 rated product. It weighs 0.22kg. The main application of this module is industry and building/service sector. This product is certified by C-Tick, GL, UL, CSA and GOST. It meets EN/IEC 60068-2-27 Ea, EN/IEC 61000-4-5, EN/IEC 61000-4-12 and EN/IEC 61000-4-4 L3 standards. Easy to use, Zelio Logic provides a real alternative solutions based on cabled logic or specific cards.

Product identifiers

SKU: SR3XT141JD
EAN: 3389119203951
GTIN: 3389119203951
MPN: SR3XT141JD

Price range: £ 114.02 - £ 115.73 Excl. VAT


Categories

Features

Depth
59.5 mm
Width
72 mm
Height
90 mm
Expandable
FALSE
Redundancy
FALSE
Basic device
TRUE
With display
FALSE
IO link master
FALSE
Expansion device
TRUE
Power consumption
1.1 W
Supply voltage DC
Switching current
8 A
With relay output
TRUE
Radio standard GSM
FALSE
Radio standard GPRS
FALSE
Radio standard UMTS
FALSE
Rack-assembly possible
FALSE
With optical interface
FALSE
With time switch clock
FALSE
Front built-in possible
TRUE
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
8
Radio standard Bluetooth
FALSE
Degree of protection (IP)
IP20
Number of analogue inputs
0
Number of digital outputs
6
Number of analogue outputs
0
Radio standard WLAN 802.11
FALSE
SIL according to IEC 61508
None
Suitable for rail mounting
TRUE
Number of HW-interfaces USB
0
Supporting protocol for ASI
FALSE
Supporting protocol for CAN
FALSE
Supporting protocol for KNX
FALSE
Supporting protocol for LON
FALSE
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
FALSE
Voltage type (supply voltage)
AC/DC
Wall mounting/direct mounting
TRUE
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
FALSE
Supporting protocol for SERCOS
FALSE
Supporting protocol for TCP/IP
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
FALSE
Supporting protocol for INTERBUS
FALSE
Supporting protocol for PROFIBUS
FALSE
Appendant operation agent (Ex ia)
FALSE
Appendant operation agent (Ex ib)
FALSE
Explosion safety category for gas
None
Supporting protocol for DeviceNet
FALSE
Supporting protocol for PROFIsafe
FALSE
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for Data-Highway
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for INTERBUS-Safety
FALSE
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for other bus systems
FALSE
Certified for UL hazardous location class I
FALSE
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
FALSE
Certified for UL hazardous location class II
FALSE
Certified for UL hazardous location class III
FALSE
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
FALSE
Certified for UL hazardous location division 2
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Certified for UL hazardous location group D (propane)
FALSE
Certified for UL hazardous location group B (hydrogen)
FALSE
Certified for UL hazardous location group C (ethylene)
FALSE
Certified for UL hazardous location group A (acetylene)
FALSE
Certified for UL hazardous location group E (metal dusts)
FALSE
Certified for UL hazardous location group F (carbonaceous dusts)
FALSE
Certified for UL hazardous location group G (non-conductive dusts)
FALSE