CANopen interface block - IP67 - 16 I/O - M12

CANopen interface block - IP67 - 16 I/O - M12

This product is part of the Modicon TM7 range, modular I/O system. This CANopen interface block provides 16 I/O blocks with positive discrete input logic and transistor discrete output. It is an interface block with a rated operational voltage of 24V DC, a discrete I/O voltage of 24V DC and a discrete input current of 4.4mA. It is an IP67 rated product. It weighs 0.32kg. This product is certified by ATEX II 3g EEx nA II T5, C-Tick, CE, CURus and GOST-R. It meets IEC 61131-2 standards. This range is compatible with Modicon LMC058 motion controller and Modicon M258 logic controller. It can be fixed with screws. Dust/damp-proof and robust, the modular IO system Modicon TM7 enables connection of sensors and actuators at the heart of processes or machines in harsh environments. The Modicon TM7 CANopen interface blocks enable sensors and actuators distributed over machines to be connected via the CANopen fieldbus. These interface blocks communicate on the bus.

Product identifiers

SKU: TM7NCOM16A
EAN: 3595864092805
GTIN: 3595864092805
MPN: TM7NCOM16A

V+ Loyalty points:

308

Price: £ 615.00 Excl. VAT


Categories

Features

Depth
42 mm
Width
53 mm
Height
155 mm
Redundancy
no
IO link master
no
Power consumption
1.1 W
Transmission rate
-
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
With optical interface
no
Radio standard Bluetooth
no
Type of data transmission
Other
With potential separation
no
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Number of HW-interfaces CAN
0
Number of HW-interfaces USB
0
Supporting protocol for ASI
no
Supporting protocol for CAN
yes
Supporting protocol for KNX
no
Supporting protocol for LON
no
Number of HW-interfaces other
16
Number of interfaces PROFINET
0
Suitable for safety functions
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
Other
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
Other
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no