Speed monitoring 2 TTL encoder expansion module with screw term

Speed monitoring 2 TTL encoder expansion module with screw term

This Modicon MCM safe speed monitoring module has 2 TTL encoder inputs (with RJ45 connectors) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Product identifiers

SKU: XPSMCMEN0200TT
EAN: 3606480748783
GTIN: 3606480748783
MPN: XPSMCMEN0200TT

V+ Loyalty points:

278

Price: £ 806.39 Excl. VAT


Categories

Features

Depth
114.5 mm
Model
Expansion device
Width
22.5 mm
Height
99 mm
EFDE0031
TRUE
Release-delay
With start input
FALSE
Control voltage 1
Control voltage 2
Evaluation inputs
Other
Power consumption
1.1 W
Supply voltage DC
Operating voltage DC
Rated switch current
-
With muting function
FALSE
With feedback circuit
FALSE
With detachable clamps
TRUE
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
With approval for BG BIA
FALSE
Type of control voltage 1
-
Type of control voltage 2
-
Operating voltage AC 50 Hz
Operating voltage AC 60 Hz
SIL according to IEC 61508
3
Suitable for rail mounting
TRUE
Type of electric connection
Screw connection
Voltage type (supply voltage)
DC
With approval according to UL
TRUE
Suitable for monitoring of valves
FALSE
Stop category according to IEC 60204
0 + 1
Type of safety according to IEC 61496-1
None
Suitable for monitoring of tactile sensors
FALSE
Suitable for monitoring of magnetic switches
FALSE
Suitable for monitoring of position switches
FALSE
Performance level according to EN ISO 13849-1
Level e
Suitable for monitoring of proximity switches
TRUE
Suitable for monitoring of emergency-stop circuits
FALSE
Number of outputs, safety related, delayed, with contact
0
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, signalling function, delayed, with contact
0
Suitable for monitoring of optoelectronic protection equipment
FALSE
Number of outputs, signalling function, delayed, semiconductors
0
Number of outputs, signalling function, undelayed, with contact
0
Number of outputs, signalling function, undelayed, semiconductors
0