Basic digital input module STB - 24 V DC - 16 I
This input module is part of the Modicon STB range, an offer of IP20 modular distributed I/Os on multiple networks and fieldbus. This basic digital input module offers 16 inputs with positive discrete input logic. It is a module with discrete input voltage of 24V DC. There is an insulation between channels and logic bus at 1500V for 1 minute. It is an IP20 rated product. Its dimensions are 125mm (width) x 65.1mm (depth) x 18.4mm (height). It weighs 0.086kg. It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines. This product is certified by CE, FM Class 1 Division 2, CSA and UL. It meets EN/IEC 61131-2 type 3 standard. It is compatible with I/O base STBXBA3000 and power distribution module STBPDT3100/3105. Advantys distributed I/O solutions are simple, open and flexible, meeting needs in every stage of the product life cycle. For distributed connection to sensors and actuators from a PLC with prefabricated cables.
Product identifiers
SKU: STBDDI3725
EAN: 3595863843453
GTIN: 3595863843453
MPN: STBDDI3725
Loyalty points:
57
Price: £ 113.00 Excl. VAT
Categories
Features
|
Depth
|
65.1 mm
|
|
Width
|
125 mm
|
|
Height
|
18.4 mm
|
|
IO link master
|
no
|
|
Output current
|
-
|
|
System accessory
|
yes
|
|
Supply voltage DC
|
|
|
Radio standard GSM
|
no
|
|
Radio standard GPRS
|
no
|
|
Radio standard UMTS
|
no
|
|
Rack-assembly possible
|
yes
|
|
Type of digital output
|
None
|
|
Type of output voltage
|
AC/DC
|
|
With optical interface
|
no
|
|
Front built-in possible
|
no
|
|
Supply voltage AC 50 Hz
|
|
|
Supply voltage AC 60 Hz
|
|
|
Number of digital inputs
|
16
|
|
Radio standard Bluetooth
|
no
|
|
Degree of protection (IP)
|
IP20
|
|
Input current at signal 1
|
4.5 mA
|
|
Number of digital outputs
|
0
|
|
Permitted voltage at input
|
|
|
Radio standard WLAN 802.11
|
no
|
|
SIL according to IEC 61508
|
None
|
|
Suitable for rail mounting
|
no
|
|
Digital inputs configurable
|
no
|
|
Number of HW-interfaces USB
|
0
|
|
Permitted voltage at output
|
|
|
Supporting protocol for ASI
|
no
|
|
Supporting protocol for CAN
|
no
|
|
Supporting protocol for KNX
|
no
|
|
Supporting protocol for LON
|
no
|
|
Time delay at signal change
|
|
|
Type of electric connection
|
Screw connection
|
|
Digital outputs configurable
|
no
|
|
Number of HW-interfaces other
|
0
|
|
Number of interfaces PROFINET
|
0
|
|
Suitable for safety functions
|
no
|
|
Voltage type (supply voltage)
|
AC/DC
|
|
Wall mounting/direct mounting
|
no
|
|
Number of HW-interfaces RS-232
|
0
|
|
Number of HW-interfaces RS-422
|
0
|
|
Number of HW-interfaces RS-485
|
0
|
|
Supporting protocol for Modbus
|
no
|
|
Supporting protocol for SERCOS
|
no
|
|
Supporting protocol for TCP/IP
|
no
|
|
Supporting protocol for SUCONET
|
no
|
|
Type of voltage (input voltage)
|
AC/DC
|
|
Number of HW-interfaces parallel
|
0
|
|
Number of HW-interfaces wireless
|
0
|
|
Supporting protocol for EtherCAT
|
no
|
|
Supporting protocol for INTERBUS
|
no
|
|
Supporting protocol for PROFIBUS
|
no
|
|
Appendant operation agent (Ex ia)
|
no
|
|
Appendant operation agent (Ex ib)
|
no
|
|
Explosion safety category for gas
|
None
|
|
Supporting protocol for DeviceNet
|
no
|
|
Supporting protocol for PROFIsafe
|
no
|
|
Explosion safety category for dust
|
None
|
|
Number of HW-interfaces serial TTY
|
0
|
|
Supporting protocol for EtherNet/IP
|
no
|
|
Supporting protocol for PROFINET IO
|
no
|
|
Supporting protocol for SafetyBUS p
|
no
|
|
Supporting protocol for Data-Highway
|
no
|
|
Supporting protocol for PROFINET CBA
|
no
|
|
Supporting protocol for INTERBUS-Safety
|
no
|
|
Supporting protocol for DeviceNet Safety
|
no
|
|
Supporting protocol for other bus systems
|
no
|
|
Certified for UL hazardous location class I
|
no
|
|
Number of HW-interfaces industrial Ethernet
|
0
|
|
Short-circuit protection, outputs available
|
no
|
|
Supporting protocol for Foundation Fieldbus
|
no
|
|
Certified for UL hazardous location class II
|
no
|
|
Certified for UL hazardous location class III
|
no
|
|
Performance level according to EN ISO 13849-1
|
None
|
|
Certified for UL hazardous location division 1
|
no
|
|
Certified for UL hazardous location division 2
|
no
|
|
Supporting protocol for AS-Interface Safety at Work
|
no
|
|
Certified for UL hazardous location group D (propane)
|
no
|
|
Certified for UL hazardous location group B (hydrogen)
|
no
|
|
Certified for UL hazardous location group C (ethylene)
|
no
|
|
Fieldbus connection over separate bus coupler possible
|
yes
|
|
Certified for UL hazardous location group A (acetylene)
|
no
|
|
Certified for UL hazardous location group E (metal dusts)
|
no
|
|
Certified for UL hazardous location group F (carbonaceous dusts)
|
no
|
|
Certified for UL hazardous location group G (non-conductive dusts)
|
no
|