Basic digital input module STB - 24 V DC - 16 I

Basic digital input module STB - 24 V DC - 16 I

This input module is part of the Modicon STB range, an offer of IP20 modular distributed I/Os on multiple networks and fieldbus. This basic digital input module offers 16 inputs with positive discrete input logic. It is a module with discrete input voltage of 24V DC. There is an insulation between channels and logic bus at 1500V for 1 minute. It is an IP20 rated product. Its dimensions are 125mm (width) x 65.1mm (depth) x 18.4mm (height). It weighs 0.086kg. It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines. This product is certified by CE, FM Class 1 Division 2, CSA and UL. It meets EN/IEC 61131-2 type 3 standard. It is compatible with I/O base STBXBA3000 and power distribution module STBPDT3100/3105. Advantys distributed I/O solutions are simple, open and flexible, meeting needs in every stage of the product life cycle. For distributed connection to sensors and actuators from a PLC with prefabricated cables.

Product identifiers

SKU: STBDDI3725
EAN: 3595863843453
GTIN: 3595863843453
MPN: STBDDI3725

V+ Loyalty points:

57

Price: £ 113.00 Excl. VAT


Categories

Features

Depth
65.1 mm
Width
125 mm
Height
18.4 mm
IO link master
no
Output current
-
System accessory
yes
Supply voltage DC
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
yes
Type of digital output
None
Type of output voltage
AC/DC
With optical interface
no
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
16
Radio standard Bluetooth
no
Degree of protection (IP)
IP20
Input current at signal 1
4.5 mA
Number of digital outputs
0
Permitted voltage at input
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
no
Digital inputs configurable
no
Number of HW-interfaces USB
0
Permitted voltage at output
Supporting protocol for ASI
no
Supporting protocol for CAN
no
Supporting protocol for KNX
no
Supporting protocol for LON
no
Time delay at signal change
Type of electric connection
Screw connection
Digital outputs configurable
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
AC/DC
Wall mounting/direct mounting
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Type of voltage (input voltage)
AC/DC
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
None
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Number of HW-interfaces industrial Ethernet
0
Short-circuit protection, outputs available
no
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Fieldbus connection over separate bus coupler possible
yes
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no