HQL LED FILAMENT PERFORMANCE 3600LM 19.4W 827 E27

HQL LED FILAMENT PERFORMANCE 3600LM 19.4W 827 E27

Product benefits
  • Same design as traditional HQL lamps with frosted, ellipsoid full glass bulb
  • Saves up to 82 % energy when used as replacement for mercury vapor lamps (HQL)
  • Full use of reflector of existing luminaire thanks to 360 degree beam angle
  • Very light weight product
  • Low maintenance costs thanks to long lifetime
  • Instant 100 % light, no warm-up time
Areas of application
  • Streets
  • Area lighting
  • Pedestrian zones
  • Parks
  • Outdoor applications only in suitable luminaires
Product features
  • Replacement for HQL: Suitable for operation with conventional control gear (CCG) for HQL or 230 V mains
  • Replacement for other HID: Suitable for operation with line voltage without control gear
  • Very high efficiency of 185 lm/W
  • Power factor: 0.9
  • Type of protection: IP65
  • High surge protection: up to 4 kV (L-N)
  • Very wide ambient temperature range of -20...+60 °C
  • ENEC-certified safety
Safety advice
  • Not suitable for operation with ignitors.
  • Operation on the capacitor can lead to a reduction of the power factor of the system.
  • When installed horizontally, the tc point of the lamp is located on the top side of the lamp.
  • Use in tight luminaires and luminaires with tight reflectors not recommended.
  • Only suitable for temperatures of up to 60 °C inside of the luminaire. Use in tight luminaires and luminaires with tight reflectors not recommended.
  • All electrical connections must be made by a qualified person.
References / Links

Product identifiers

SKU: 4099854469985
EAN: 4099854469985
GTIN: 4099854469985
MPN: 4099854469985

Price: £ 0.00 Excl. VAT

Specifications

Lifespan

Lifespan L70/B50 at 25 °C 60000 h
Number of switching cycles 100000
Lumen maintenance at end of service lifetime 0.70
Rated lamp survival factor at 6,000 h ≥ 0.90

Capabilities

Dimmable No

Electrical data

Nominal wattage 19.4 W
Construction wattage 19.40 W
Nominal voltage 220…240 V
Operating mode CCG, AC Mains
Nominal current 86 mA
Inrush current 7.32 A
Mains frequency 50/60 Hz
Max. lamp number on MCB B10 A - CCG without compensation 21
Max. lamp number on MCB B16 A 22
Max. lamp number on MCB B16 A - CCG with compensation 7
Power factor λ > 0.90

Documents

Documents and certificates

Data sheet
Open

Documents And Certificates

User instruction / safety instructions
Open
Legal information – Informationstext 18 Abs 4 ElektroG
Open
Legal information – Safety Insert G11201307
Open
Declarations of conformity UKCA – FIL P lamp
Open

Photometric And Lighting Design Files

IES file (IES) – HQL LED FIL P 3600LM 19.4W 827 E27
Open
LDT file (Eulumdat) – HQL LED FIL P 3600LM 19.4W 827 E27
Open
UGR file (UGR table) – HQL LED FIL P 3600LM 19.4W 827 E27
Open