Enerlin'X I/O application module

Enerlin'X I/O application module

This I/O module is an Input/Output application module and it is part of EnerlinX communication system. This I/O module is compatible with Masterpact, Compact and PowerPact devices. It is used for protection, circuit breaker control, motor control, energy management and monitoring applications. It provides six digital inputs, three digital outputs and one analog input. It is equipped on the top with one 24VDC screw clamp terminal block and one terminal block for the 6 digital inputs. There are two RJ45 sockets on the bottom for ULP, and 4 terminal blocks for the digital outputs and analog input. The I/O module is a DIN rail mounting device and its dimensions are 72mm x 116mm x 71mm. The protection degree is IP4x on the front face and IP2x on the connectors. The I/O module is entirely part of the EcoStruxure Power architecture and Ethernet ready smart panels. The I/O module can be configured and updated (firmware) using EcoStruxure Power Commission software.

Product identifiers

SKU: LV434063
EAN: 3606480631146
GTIN: 3606480631146
MPN: LV434063

Voltimum+ Loyalty Programme Loyalty points: 90

Price: £ 541.00 Excl. VAT

Specifications

Depth 70.6 mm
Width 71.7 mm
Height 116 mm
IO link master yes
System accessory no
Supply voltage DC
Radio standard GSM no
Radio standard GPRS no
Rack-assembly possible no
Type of output voltage AC
Analogue input, current no
Front built-in possible no
Supply voltage AC 60 Hz
Analogue output, current no
Number of digital inputs 6
Degree of protection (IP) IP2X
Number of analogue inputs 1
Number of analogue outputs 0
Radio standard WLAN 802.11 no
Suitable for rail mounting yes
Number of HW-interfaces USB 0
Supporting protocol for CAN no
Supporting protocol for LON no
Type of electric connection Screw connection
Analogue inputs configurable yes
Analogue outputs configurable no
Number of interfaces PROFINET 0
Voltage type (supply voltage) DC
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 0
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces parallel 0
Output current at digital output 5 A
Supporting protocol for EtherCAT no
Supporting protocol for PROFIBUS no
Appendant operation agent (Ex ib) no
Resolution of the analogue inputs -
Supporting protocol for PROFIsafe no
Explosion safety category for dust -
Resolution of the analogue outputs -
Supporting protocol for EtherNet/IP yes
Supporting protocol for SafetyBUS p no
Supporting protocol for Data-Highway no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems no
Number of HW-interfaces industrial Ethernet 0
Certified for UL hazardous location class II no
Performance level according to EN ISO 13849-1 -
Certified for UL hazardous location division 2 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Fieldbus connection over separate bus coupler possible no
Certified for UL hazardous location group E (metal dusts) no
Certified for UL hazardous location group G (non-conductive dusts) no