Distributed analog/discrete I/O Modicon Momentum

Distributed analog/discrete I/O Modicon Momentum

This product is part of the Modicon Momentum range, an offer of controller and IP20 monoblock I/Os for distributed control architecture. This distributed analogue/discrete module has 1 group of 2 discrete outputs, 4 discrete inputs, 4 analogue differential inputs and 2 analogue output with positive discrete input logic. It is an analogue/discrete module with a rated supply voltage of 24V DC, a discrete output current of 1A per point, 2A per group, 2A per module and a maximum power dissipation of 6W. It is furnished with 2 connectors for removable terminal blocks. Analogue input range of this product is ±10V, ±20mA, ±5V, 1V to 5V, 4mA to 20mA and analogue output range is ±10V 12bit and 0mA to 20mA 12bit. Its dimensions are 141.5mm (width) x 47.5mm (depth) x 125mm (height) and weighs 0.24kg. The main application of this module is infrastructures and energy, material handling, simple machine control. This product is certified by CE, FM Class 1 Division 2, CSA and UL. Momentum is a flexible, modular family of fundamental components that easily snap together and can be configured for a wide range of distributed I/O and control applications. System with 4 fundamental components that easily snap together in various combinations to form versatile control systems or sub-systems.

Product identifiers

SKU: 170AMM09000
EAN: 3595861000292
GTIN: 3595861000292
MPN: 170AMM09000

V+ Loyalty points:

444

Price: £ 888.00 Excl. VAT


Categories

Features

Depth
47.5 mm
Width
141.5 mm
Height
125 mm
IO link master
no
System accessory
no
Supply voltage DC
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
no
Type of digital output
Other
Type of output voltage
DC
With optical interface
no
Analogue input, current
no
Analogue input, voltage
yes
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Analogue input, resistor
no
Analogue output, current
yes
Analogue output, voltage
yes
Number of digital inputs
4
Radio standard Bluetooth
no
Degree of protection (IP)
Other
Input current at signal 1
20 mA
Number of analogue inputs
5
Number of digital outputs
1
Number of analogue outputs
2
Permitted voltage at input
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
no
Digital inputs configurable
no
Number of HW-interfaces USB
0
Supporting protocol for ASI
no
Supporting protocol for CAN
no
Supporting protocol for KNX
no
Supporting protocol for LON
no
Time delay at signal change
Type of electric connection
Other
Analogue input, thermocouple
no
Analogue inputs configurable
no
Digital outputs configurable
no
Analogue outputs configurable
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
DC
Wall mounting/direct mounting
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Type of voltage (input voltage)
DC
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Output current at digital output
0.02 A
Output voltage at digital output
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
Other
Resolution of the analogue inputs
12 Bit
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Analogue input signal configurable
no
Explosion safety category for dust
Other
Number of HW-interfaces serial TTY
0
Resolution of the analogue outputs
12 Bit
Analogue output signal configurable
no
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Analogue input, resistor temperature
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
no
Performance level according to EN ISO 13849-1
None
Short-circuit protection, digital outputs available
yes
Supporting protocol for AS-Interface Safety at Work
no
Fieldbus connection over separate bus coupler possible
no