PowerLogic HDPM6000, Base unit calibrated for 60Hz, 480v

PowerLogic HDPM6000, Base unit calibrated for 60Hz, 480v

This is an integrated solution for monitoring multi-circuits and power quality by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres, facilities and energy management in buildings. Allow monitoring of loads up to 4000A with utility grade accuracy on all branch channels. The head unit measure the voltage reference and aggregate data from the connected elements. Allow measurement of energy, power demand, instantaneous power, current, harmonic, voltage and more - in total or per phases. Devices can be connected in dasy-chain thanks to CAT5 or CAT6 straight-through Ethernet cable. The HDPM6000 series can also maintain multiple, concurrent sessions with EPMS, DCIM or BMS applications via the Modbus, SNMP and BACnet IP protocols. The unit need to be supplied in 24VDC, an adaptator is available to convert 480VAC (264V to 575VAC) network to needed voltage. Input reference voltage can be configured between 120 to 480VAC, frequency is calibrated for 50 or 60Hz. The head unit dimensions are 222mm in width, 51mm in height and 122mm in depth connector included. The elements can be mounted on a DIN rail thanks to the clips at the back side. Could be associated with a touchscreen display, that could provide information from up to 4 head units. Integration of EcoStruxure Power Monitoring Expert and Power Operation features for possible software monitoring. The system PowerLogic HDPM6000 can help you identify increased harmonics in the rack servers to detect a potential disruption. Thanks to daisy-chain, it is possible to connect additional modules if the head unit capacity isn't exceeded.

Product identifiers

SKU: METSEHDPM6S480VC
EAN: 3606481985880
GTIN: 3606481985880
MPN: METSEHDPM6S480VC

V+ Loyalty points:

1217

Price: £ 2,433.00 Excl. VAT

Specifications

Depth 104.65 mm
Model Compact
Width 221.74 mm
Height 51.04 mm
Redundancy no
Memory size 8 kByte
With display no
IO link master no
System accessory no
Radio standard GSM no
Radio standard UMTS no
With optical interface no
Number of relay outputs 0
Supply voltage AC 60 Hz
Radio standard Bluetooth no
Number of analogue inputs 8
Number of analogue outputs 0
SIL according to IEC 61508 None
Number of HW-interfaces USB 0
Supporting protocol for CAN no
Supporting protocol for LON no
Supporting protocol for DNP3 no
Number of interfaces PROFINET 0
Voltage type (supply voltage) DC
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 1
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for IEC 60870 no
Additional program memory possible no
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems no
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Certified for UL hazardous location group A (acetylene) no
Certified for UL hazardous location group F (carbonaceous dusts) no