EasyLogic PM2220, Power & Energy meter, up to the 15th harmonic, LCD display, RS485, class 1

EasyLogic PM2220, Power & Energy meter, up to the 15th harmonic, LCD display, RS485, class 1

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 15th Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).

Product identifiers

SKU: METSEPM2220
EAN: 3606480800177
GTIN: 3606480800177
MPN: METSEPM2220

V+ Loyalty points:

137

Price: £ 55.43 Excl. VAT

Specifications

Depth 65.43 mm
Model Measurement transformer
Width 96 mm
Height 96 mm
Display LCD
Pole type Three conductor/four conductor
Voltmeter yes
Calibrated no
Power factor yes
Pulse counter yes
Remote display no
Mounting method Front mounting
Sampling frequency 6400 Hz
Nominal current (In) 5 A
Step angle (cos phi) no
Harmonics measurement yes
Supply voltage AC 50 Hz
With firmware signature no
Number of analogue inputs 0
Number of analogue outputs 0
Display resolution (vertical) 128 px
Measuring range for frequency
Number of Ethernet connections 0
With audit logging (audit log) no
Supporting protocol for PROFIBUS no
Wth communication interface M-Bus no
Supporting protocol for PROFINET IO no
Number of current measurement inputs 6
Degree of protection (IP), front side Other
With Role Based Access Control (RBAC) no
Supporting protocol for other bus systems no
Connectable conductor cross section solid-core
Accuracy class active energy according to IEC 62053-22 Other