This product is part of the Modicon TM5 range, an High-Performance and Safe IP20 Modular I/O System. This is a bus coupler designed for creating distributed IO islands on CANopen fieldbus, exchanging data between controller and distributed IO. Its access method is based on CSMA-MA, multi-master protocol. This is a bus coupler module designed for creating distributed IO islands on the Canopen fieldbus. This bus coupler works with an electronic power distribution module, a bus base and a terminal block. It has a 9-way SUB-D connector ISO 11898, with a 10 to 1000 Kbps data transmission rate. It weighs 0.080kg. It measures 25mm wide, 99mm high, 75mm deep. The Modicon TM5 meets the typical requirements of production and packaging machinery, as well as material handling and assembly systems. This product is certified by GOST-R, C-Tick, cULus and CSA. It meets IEC 61131-2, UL 508, CSA C22.2 No 213 and CSA C22.2 No 142 standards. It is compatible with Modicon M258 logic controllers, Modicon LMC058/LMC078 motion controllers. It is installed by mounting on a 35mm DIN rail. This modular IO system provides a flexible and scalable configuration of remote or distributed IO islands by connection with Modicon and PacDrive 3 controllers. Flexible and scalable, designed for complex machines.

Product identifiers

SKU: TM5NCO1
EAN: 3595864093031
GTIN: 3595864093031
MPN: TM5NCO1

V+ Loyalty points:

65

Price: £ 129.00 Excl. VAT


Categories

Features

Depth
75 mm
Width
37.5 mm
Height
99 mm
Redundancy
no
IO link master
no
Power consumption
7.2 W
Transmission rate
1000 kBit/s
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
With optical interface
no
Radio standard Bluetooth
no
Type of data transmission
Other
With potential separation
no
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Number of HW-interfaces CAN
1
Number of HW-interfaces USB
0
Supporting protocol for ASI
no
Supporting protocol for CAN
yes
Supporting protocol for KNX
no
Supporting protocol for LON
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
None
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no