Technical Data
Main Features
Number of strands per conductor
-
Strand diameter
-
Nominal cross section conductor
10 mm²
Material core insulation
-
Core identification
Colour
Weight
850 kg/km
Drain wire
-
Nominal voltage U
1000 V
Stranding element
No
Colour outer sheath
Other
Shape of conductor
-
Conductor material
-
Screen over stranding element
None
Screen over stranding
None
Material outer sheath
-
Conductor category
Class 5 = flexible
Armouring/reinforcement
-
Permitted cable outer temperature during assembling/handling
Permitted cable outer temperature after assembling without vibration
-25 - 90 °C
Torsion resistant
-
Number of stranding elements
-
Nominal cross section pilot/reduced conductors
-
Number of pilot/reduced conductors
-
Nominal voltage U0
600 V
Screen
-
Number of cores
5
Suspension element
None
Halogen free according to EN IEC 60754-2
-
Cable width approx.
38.6 mm
Cable height approx.
10.1 mm
Low smoke according to EN IEC 61034-2
-
Max. conductor temperature
-
Protective barrier
-
Outer diameter approx.
-
With protective conductor
yes
Oil resistant according to EN IEC 60811-404
no
Low temperature resistant according to EN 60811-504+505+506
-
Conductor surface
Bare
Reaction-to-fire according to EN 13501-6: Class
B2ca
Reaction-to-fire according to EN 13501-6: Smoke production
s1
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
d0
Reaction-to-fire according to EN 13501-6: Acidity
a1
AWG size
-
Nominal cross section conductor (AWG)
-
Nominal cross section pilot/reduced conductors (AWG)
-
Min. permitted bending radius, moving application with forced guidance
-
Min. permitted bending radius, moving application/free movement
-
Min. permitted bending radius, stationary application/permanent installation
60 mm
Specification core insulation
-
Specification material outer sheath
-
Material armouring
-
Cable geometry
Flat
Conductor resistance at 20 °C
1.91 Ohm/km
Core identification according to HD 308 S2
-
Max. tensile strength during installation
-
Flame retardant according to IEC 60332-1-2
-
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
-
Flame retardant according to IEC 60332-3-22 (Cat A)
-
Flame retardant according to IEC 60332-3-23 (Cat B)
-
Flame retardant according to IEC 60332-3-24 (Cat C)
-
Flame retardant according to IEC 60332-3-25 (Cat D)
-
Halogen free according to EN IEC 60754-1
-
Halogen free according to EN IEC 60754-3
-
Downloads

Flat cable;B2ca;5G 10 mm²;light gray
Product details
SKU Code: 897-1052
EAN Code: 4045454006235
Minimum order: 1
This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.
No Availability (0 sellers)
Technical Data
Main Features
Number of strands per conductor
-
Strand diameter
-
Nominal cross section conductor
10 mm²
Material core insulation
-
Core identification
Colour
Weight
850 kg/km
Drain wire
-
Nominal voltage U
1000 V
Stranding element
No
Colour outer sheath
Other
Shape of conductor
-
Conductor material
-
Screen over stranding element
None
Screen over stranding
None
Material outer sheath
-
Conductor category
Class 5 = flexible
Armouring/reinforcement
-
Permitted cable outer temperature during assembling/handling
Permitted cable outer temperature after assembling without vibration
-25 - 90 °C
Torsion resistant
-
Number of stranding elements
-
Nominal cross section pilot/reduced conductors
-
Number of pilot/reduced conductors
-
Nominal voltage U0
600 V
Screen
-
Number of cores
5
Suspension element
None
Halogen free according to EN IEC 60754-2
-
Cable width approx.
38.6 mm
Cable height approx.
10.1 mm
Low smoke according to EN IEC 61034-2
-
Max. conductor temperature
-
Protective barrier
-
Outer diameter approx.
-
With protective conductor
yes
Oil resistant according to EN IEC 60811-404
no
Low temperature resistant according to EN 60811-504+505+506
-
Conductor surface
Bare
Reaction-to-fire according to EN 13501-6: Class
B2ca
Reaction-to-fire according to EN 13501-6: Smoke production
s1
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
d0
Reaction-to-fire according to EN 13501-6: Acidity
a1
AWG size
-
Nominal cross section conductor (AWG)
-
Nominal cross section pilot/reduced conductors (AWG)
-
Min. permitted bending radius, moving application with forced guidance
-
Min. permitted bending radius, moving application/free movement
-
Min. permitted bending radius, stationary application/permanent installation
60 mm
Specification core insulation
-
Specification material outer sheath
-
Material armouring
-
Cable geometry
Flat
Conductor resistance at 20 °C
1.91 Ohm/km
Core identification according to HD 308 S2
-
Max. tensile strength during installation
-
Flame retardant according to IEC 60332-1-2
-
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
-
Flame retardant according to IEC 60332-3-22 (Cat A)
-
Flame retardant according to IEC 60332-3-23 (Cat B)
-
Flame retardant according to IEC 60332-3-24 (Cat C)
-
Flame retardant according to IEC 60332-3-25 (Cat D)
-
Halogen free according to EN IEC 60754-1
-
Halogen free according to EN IEC 60754-3
-
Downloads