Flat cable;B2ca;5G 10 mm²;light gray Zoomed Image
WAGO

Flat cable;B2ca;5G 10 mm²;light gray

Flat cable; B2ca; 5G 10 mm²; halogen-free; 3L + N + PE; 0.6/1 kV; 10,00 mm²; light gray

Product details

SKU Code: 897-1052

EAN Code: 4045454006235

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

Technical Data

Main Features

Number of strands per conductor

-

Strand diameter

-

Nominal cross section conductor

10 mm²

Material core insulation

-

Core identification

Colour

Weight

850 kg/km

Drain wire

-

Nominal voltage U

1000 V

Stranding element

No

Colour outer sheath

Other

Shape of conductor

-

Conductor material

-

Screen over stranding element

None

Screen over stranding

None

Material outer sheath

-

Conductor category

Class 5 = flexible

Armouring/reinforcement

-

Permitted cable outer temperature during assembling/handling

Permitted cable outer temperature after assembling without vibration

-25 - 90 °C

Torsion resistant

-

Number of stranding elements

-

Nominal cross section pilot/reduced conductors

-

Number of pilot/reduced conductors

-

Nominal voltage U0

600 V

Screen

-

Number of cores

5

Suspension element

None

Halogen free according to EN IEC 60754-2

-

Cable width approx.

38.6 mm

Cable height approx.

10.1 mm

Low smoke according to EN IEC 61034-2

-

Max. conductor temperature

-

Protective barrier

-

Outer diameter approx.

-

With protective conductor

yes

Oil resistant according to EN IEC 60811-404

no

Low temperature resistant according to EN 60811-504+505+506

-

Conductor surface

Bare

Reaction-to-fire according to EN 13501-6: Class

B2ca

Reaction-to-fire according to EN 13501-6: Smoke production

s1

Reaction-to-fire according to EN 13501-6: Flaming droplets/particles

d0

Reaction-to-fire according to EN 13501-6: Acidity

a1

AWG size

-

Nominal cross section conductor (AWG)

-

Nominal cross section pilot/reduced conductors (AWG)

-

Min. permitted bending radius, moving application with forced guidance

-

Min. permitted bending radius, moving application/free movement

-

Min. permitted bending radius, stationary application/permanent installation

60 mm

Specification core insulation

-

Specification material outer sheath

-

Material armouring

-

Cable geometry

Flat

Conductor resistance at 20 °C

1.91 Ohm/km

Core identification according to HD 308 S2

-

Max. tensile strength during installation

-

Flame retardant according to IEC 60332-1-2

-

Flame retardant according to IEC 60332-3-21 (Cat A F/R)

-

Flame retardant according to IEC 60332-3-22 (Cat A)

-

Flame retardant according to IEC 60332-3-23 (Cat B)

-

Flame retardant according to IEC 60332-3-24 (Cat C)

-

Flame retardant according to IEC 60332-3-25 (Cat D)

-

Halogen free according to EN IEC 60754-1

-

Halogen free according to EN IEC 60754-3

-