Technical Data
Main Features
Supporting protocol for EtherCAT
-
Certified for UL hazardous location group A (acetylene)
-
Certified for UL hazardous location group B (hydrogen)
-
Certified for UL hazardous location group C (ethylene)
-
Certified for UL hazardous location group D (propane)
-
Certified for UL hazardous location group E (metal dusts)
-
Certified for UL hazardous location group F (carbonaceous dusts)
-
Certified for UL hazardous location group G (non-conductive dusts)
-
Certified for UL hazardous location class I
-
Certified for UL hazardous location class II
-
Certified for UL hazardous location class III
-
Certified for UL hazardous location division 1
-
Certified for UL hazardous location division 2
-
Width
108 mm
Model
Compact
Height
90 mm
Depth
55 mm
With display
no
Suitable for safety functions
no
Number of digital inputs
8
Number of digital outputs
4
Number of analogue inputs
2
Number of analogue outputs
2
Voltage type (supply voltage)
DC
Type of memory
RAM
Memory size
32768 kByte
Processing time (1K, binary operation)
-
Supporting protocol for LON
no
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
Number of HW-interfaces RS-422
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
Number of HW-interfaces parallel
Number of HW-interfaces other
With optical interface
no
Additional program memory possible
yes
Supporting protocol for TCP/IP
yes
Supporting protocol for ASI
no
Supporting protocol for PROFIBUS
no
Supporting protocol for CAN
no
Supporting protocol for INTERBUS
no
Supporting protocol for KNX
no
Supporting protocol for Modbus
yes
Supporting protocol for Data-Highway
no
Supporting protocol for DeviceNet
no
Supporting protocol for SUCONET
no
Supporting protocol for other bus systems
yes
Redundancy
no
Suitable for rail mounting
yes
Explosion safety category for gas
None
Explosion safety category for dust
None
System accessory
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Supporting protocol for SERCOS
no
Supporting protocol for INTERBUS-Safety
no
Number of interfaces PROFINET
Number of HW-interfaces wireless
Front built-in possible
no
Rack-assembly possible
no
Wall mounting/direct mounting
no
Radio standard Bluetooth
no
Radio standard WLAN 802.11
no
IO link master
no
Number of relay outputs
Max. number of time switches
Performance level according to EN ISO 13849-1
-
Supporting protocol for AS-Interface Safety at Work
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for EtherNet/IP
yes
Supporting protocol for Foundation Fieldbus
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for PROFINET IO
no
Supporting protocol for PROFIsafe
no
Supporting protocol for SafetyBUS p
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Supply voltage DC
24 - 24 V
Radio standard GPRS
no
Radio standard GSM
no
Radio standard UMTS
no
Long-Term Evolution (LTE)
-
SIL according to IEC 61508
-
Supporting protocol for IEC 61850 Ethernet
yes
Supporting protocol for DNP3
yes
Supporting protocol for IEC 60870
yes
Downloads

Compact Controller 100;8DI 4DO 2AI 2AO 2NI1K/PT1K 1RS485;2 x ETHERNET
Product details
SKU Code: 751-9301
EAN Code: 4066966192865
Minimum order: 1
Available for Back Order (1 seller)
Availability
Out of Stock
£464.24
Back Order Manufacturer lead time of 6 weeks.
£725.38
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £464.24 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 6 weeks. | £725.38 Ex. VAT |
Price:
£725.38 ex. vat
Technical Data
Main Features
Supporting protocol for EtherCAT
-
Certified for UL hazardous location group A (acetylene)
-
Certified for UL hazardous location group B (hydrogen)
-
Certified for UL hazardous location group C (ethylene)
-
Certified for UL hazardous location group D (propane)
-
Certified for UL hazardous location group E (metal dusts)
-
Certified for UL hazardous location group F (carbonaceous dusts)
-
Certified for UL hazardous location group G (non-conductive dusts)
-
Certified for UL hazardous location class I
-
Certified for UL hazardous location class II
-
Certified for UL hazardous location class III
-
Certified for UL hazardous location division 1
-
Certified for UL hazardous location division 2
-
Width
108 mm
Model
Compact
Height
90 mm
Depth
55 mm
With display
no
Suitable for safety functions
no
Number of digital inputs
8
Number of digital outputs
4
Number of analogue inputs
2
Number of analogue outputs
2
Voltage type (supply voltage)
DC
Type of memory
RAM
Memory size
32768 kByte
Processing time (1K, binary operation)
-
Supporting protocol for LON
no
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
Number of HW-interfaces RS-422
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
Number of HW-interfaces parallel
Number of HW-interfaces other
With optical interface
no
Additional program memory possible
yes
Supporting protocol for TCP/IP
yes
Supporting protocol for ASI
no
Supporting protocol for PROFIBUS
no
Supporting protocol for CAN
no
Supporting protocol for INTERBUS
no
Supporting protocol for KNX
no
Supporting protocol for Modbus
yes
Supporting protocol for Data-Highway
no
Supporting protocol for DeviceNet
no
Supporting protocol for SUCONET
no
Supporting protocol for other bus systems
yes
Redundancy
no
Suitable for rail mounting
yes
Explosion safety category for gas
None
Explosion safety category for dust
None
System accessory
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Supporting protocol for SERCOS
no
Supporting protocol for INTERBUS-Safety
no
Number of interfaces PROFINET
Number of HW-interfaces wireless
Front built-in possible
no
Rack-assembly possible
no
Wall mounting/direct mounting
no
Radio standard Bluetooth
no
Radio standard WLAN 802.11
no
IO link master
no
Number of relay outputs
Max. number of time switches
Performance level according to EN ISO 13849-1
-
Supporting protocol for AS-Interface Safety at Work
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for EtherNet/IP
yes
Supporting protocol for Foundation Fieldbus
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for PROFINET IO
no
Supporting protocol for PROFIsafe
no
Supporting protocol for SafetyBUS p
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Supply voltage DC
24 - 24 V
Radio standard GPRS
no
Radio standard GSM
no
Radio standard UMTS
no
Long-Term Evolution (LTE)
-
SIL according to IEC 61508
-
Supporting protocol for IEC 61850 Ethernet
yes
Supporting protocol for DNP3
yes
Supporting protocol for IEC 60870
yes