Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Fail-safe 8-channel digital input;24 VDC;PROFIsafe;yellow Zoomed Image
WAGO

Fail-safe 8-channel digital input;24 VDC;PROFIsafe;yellow

Fail-safe 8-channel digital input; 24 VDC; PROFIsafe

Product details

SKU Code: 750-660/000-001

EAN Code: 4045454611125

Minimum order: 1

Available for Back Order (1 seller)

Availability

RS Components

Back Order

£340.58

Distributor Availability Price  
RS Components Back Order £340.58 Ex. VAT

Price:

£340.58 ex. vat

Technical Data

Main Features

Supporting protocol for EtherCAT

-

Certified for UL hazardous location group A (acetylene)

-

Certified for UL hazardous location group B (hydrogen)

-

Certified for UL hazardous location group C (ethylene)

-

Certified for UL hazardous location group D (propane)

-

Certified for UL hazardous location group E (metal dusts)

-

Certified for UL hazardous location group F (carbonaceous dusts)

-

Certified for UL hazardous location group G (non-conductive dusts)

-

Certified for UL hazardous location class I

-

Certified for UL hazardous location class II

-

Certified for UL hazardous location class III

-

Certified for UL hazardous location division 1

-

Certified for UL hazardous location division 2

-

Width

24 mm

Height

100 mm

Depth

67.8 mm

Input current at signal 1

2.2 mA

Suitable for safety functions

yes

Number of digital inputs

8

Number of digital outputs

Time delay at signal change

Voltage type (supply voltage)

DC

Supporting protocol for LON

no

Number of HW-interfaces industrial Ethernet

Number of HW-interfaces RS-232

Number of HW-interfaces RS-422

Number of HW-interfaces RS-485

Number of HW-interfaces serial TTY

Number of HW-interfaces USB

Number of HW-interfaces parallel

Number of HW-interfaces other

With optical interface

no

Type of voltage (input voltage)

-

Supporting protocol for TCP/IP

no

Supporting protocol for ASI

no

Supporting protocol for PROFIBUS

no

Supporting protocol for CAN

no

Supporting protocol for INTERBUS

no

Supporting protocol for KNX

no

Supporting protocol for Modbus

no

Supporting protocol for Data-Highway

no

Supporting protocol for DeviceNet

no

Supporting protocol for SUCONET

no

Supporting protocol for other bus systems

no

Output current

-

Short-circuit protection, outputs available

no

Type of digital output

-

Type of electric connection

Spring clamp connection

Suitable for rail mounting

yes

Explosion safety category for gas

ATEX gas-ex-protection, Cat. 3G

Explosion safety category for dust

ATEX dust-ex-protection, Cat. 3D

Fieldbus connection over separate bus coupler possible

yes

System accessory

yes

Appendant operation agent (Ex ia)

no

Appendant operation agent (Ex ib)

no

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

no

Supporting protocol for INTERBUS-Safety

no

Number of interfaces PROFINET

Number of HW-interfaces wireless

Front built-in possible

no

Rack-assembly possible

no

Wall mounting/direct mounting

no

Radio standard Bluetooth

no

Radio standard WLAN 802.11

no

IO link master

no

Performance level according to EN ISO 13849-1

Level e

Supporting protocol for AS-Interface Safety at Work

no

Supporting protocol for DeviceNet Safety

no

Supporting protocol for EtherNet/IP

no

Supporting protocol for Foundation Fieldbus

no

Supporting protocol for PROFINET CBA

no

Supporting protocol for PROFINET IO

no

Supporting protocol for PROFIsafe

no

Supporting protocol for SafetyBUS p

no

Supply voltage AC 50 Hz

Supply voltage AC 60 Hz

Supply voltage DC

24 - 24 V

Permitted voltage at output

Permitted voltage at input

Type of output voltage

-

Digital inputs configurable

no

Digital outputs configurable

no

Radio standard GPRS

no

Radio standard GSM

no

Radio standard UMTS

no

SIL according to IEC 61508

2

Downloads