Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Circuit Breaker, PowerPact M, electronic trip, 800A, 3 poles, 25 kA, 600 V, lugs both ends, ABC phasing Zoomed Image
Schneider Electric

Circuit Breaker, PowerPact M, electronic trip, 800A, 3 poles, 25 kA, 600 V, lugs both ends, ABC phasing

PowerPact M-frame molded case circuit breakers provide improved performance and a compact solution for applications up to 800A. They complement the existing PowerPact P- and R-frame circuit breakers and replace the traditional MA/MH circuit breakers with a smaller footprint and competitive cost. PowerPact M-frame molded case circuit breakers are available in 300, 350, 400, 450, 500, 600, 700, and 800A ratings. PowerPact M-frame molded case circuit breakers have built-in electronic trip unit type ET 1.0 provides better accuracy than standard thermal-magnetic trip units. The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the trip point setting. (It is considered an electronic equivalent of a thermal-magnetic circuit breaker.) They also have fIxed long-time and adjustable instantaneous protection (2 to 10 times nominal ampere rating) is standard. Powerpact M-Frame breakers have the same dimensions, common mounting, bussing, cabling and door cut-out as PowerPact P-frame circuit breakers. This PowerPact M, circuit breaker has a rated current of 800A and a rated operational current of 600VAC and is an unit mount mounted breaker. This 3-pole breaker has a breaking capacity of 25kA@600VAC with an 80 % continuous current rating. This breaker complies to UL listed, IEC & CSA standards. This product has an electronic ET 1.0 trip unit trechnology and a magnetic tripping current of 1600-8000A. Dimensions for this product are 12.86 in (H),8.27 in (W), 5.77 in (D). This product comes with an 18 month warranty.

Product details

SKU Code: MJL36800

EAN Code: 785901655398

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

2047 loyalty points

Technical Data

Main Features

Type of electrical connection of main circuit

Other

Complete device with protection unit

TRUE

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

FALSE

Number of auxiliary contacts as normally closed contact

-

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as change-over contact

-

With switched-off indicator

FALSE

Overload release current setting

Rated voltage

Rated permanent current Iu

800 A

Adjustment range short-term delayed short-circuit release

Position of connection for main current circuit

Front side

Number of poles

3

Rated short-circuit breaking capacity Icu at 400 V, 50 Hz

-

Motor drive integrated

FALSE

Integrated earth fault protection

FALSE

Adjustment range undelayed short-circuit release

Degree of protection (IP)

IP20

Motor drive optional

-

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

FALSE

Downloads