Technical Data
Main Features
Armouring/reinforcement
None
Permitted cable outer temperature during assembling/handling
Torsion resistant
TRUE
With protective conductor
TRUE
Permitted cable outer temperature after assembling without vibration
Number of stranding elements
-
Low temperature resistant according to EN 60811-504+505+506
TRUE
Halogen free according to EN IEC 60754-2
TRUE
Oil resistant according to EN IEC 60811-404
TRUE
Specification material outer sheath
Polyethylene (PE)
Specification core insulation
Polyethylene (PE)
Min. permitted bending radius, stationary application/permanent installation
-
Min. permitted bending radius, moving application/free movement
-
Min. permitted bending radius, moving application with forced guidance
-
Nominal voltage U
250 V
Colour outer sheath
Black
Stranding element
Triple
Material armouring
Copper
Cable width approx.
3000 mm
Reaction-to-fire according to EN 13501-6: Acidity
a1
Cable height approx.
-
Nominal cross section pilot/reduced conductors
-
Weight
-
Number of pilot/reduced conductors
-
Low smoke according to EN IEC 61034-2
TRUE
Reaction-to-fire according to EN 13501-6: Smoke production
s2
Reaction-to-fire according to EN 13501-6: Class
Eca
Conductor resistance at 20 °C
-
Halogen free according to EN IEC 60754-3
TRUE
Conductor surface
Other
Number of strands per conductor
-
Strand diameter
-
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
d0
Material outer sheath
Other
Protective barrier
Rubber - ethylene propylene rubber (EPR)
Screen over stranding
None
Max. conductor temperature
65 °C
Nominal cross section conductor (AWG)
10 kcmil
Outer diameter approx.
14 mm
Shape of conductor
Round
Drain wire
FALSE
Screen over stranding element
None
Conductor material
Copper
Max. tensile strength during installation
-
Nominal cross section conductor
1.5 mm²
Material core insulation
Polyamide (PA)
Screen
FALSE
Nominal voltage U0
250 V
AWG size
Other
Core identification according to HD 308 S2
FALSE
Flame retardant according to IEC 60332-1-2
TRUE
Flame retardant according to IEC 60332-3-22 (Cat A)
FALSE
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
TRUE
Flame retardant according to IEC 60332-3-24 (Cat C)
TRUE
Flame retardant according to IEC 60332-3-23 (Cat B)
TRUE
Halogen free according to EN IEC 60754-1
TRUE
Flame retardant according to IEC 60332-3-25 (Cat D)
TRUE
Number of cores
3
Core identification
Colour
Suspension element
Other
Conductor category
Class 5 = flexible
Nominal cross section pilot/reduced conductors (AWG)
-
Cable geometry
Round
Downloads

Power cable 3m long for Vdc IEC LED lamps multi fixing tipe
Product details
SKU Code: NSYLAM3MDC
EAN Code: 3606481274274
Minimum order: 1
Available for Back Order (2 sellers)
Availability
Out of Stock
£34.63
Back Order
£17.89
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £34.63 Ex. VAT | |
![]() |
Back Order | £17.89 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
17 loyalty points
Price:
£17.89 ex. vat
Technical Data
Main Features
Armouring/reinforcement
None
Permitted cable outer temperature during assembling/handling
Torsion resistant
TRUE
With protective conductor
TRUE
Permitted cable outer temperature after assembling without vibration
Number of stranding elements
-
Low temperature resistant according to EN 60811-504+505+506
TRUE
Halogen free according to EN IEC 60754-2
TRUE
Oil resistant according to EN IEC 60811-404
TRUE
Specification material outer sheath
Polyethylene (PE)
Specification core insulation
Polyethylene (PE)
Min. permitted bending radius, stationary application/permanent installation
-
Min. permitted bending radius, moving application/free movement
-
Min. permitted bending radius, moving application with forced guidance
-
Nominal voltage U
250 V
Colour outer sheath
Black
Stranding element
Triple
Material armouring
Copper
Cable width approx.
3000 mm
Reaction-to-fire according to EN 13501-6: Acidity
a1
Cable height approx.
-
Nominal cross section pilot/reduced conductors
-
Weight
-
Number of pilot/reduced conductors
-
Low smoke according to EN IEC 61034-2
TRUE
Reaction-to-fire according to EN 13501-6: Smoke production
s2
Reaction-to-fire according to EN 13501-6: Class
Eca
Conductor resistance at 20 °C
-
Halogen free according to EN IEC 60754-3
TRUE
Conductor surface
Other
Number of strands per conductor
-
Strand diameter
-
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
d0
Material outer sheath
Other
Protective barrier
Rubber - ethylene propylene rubber (EPR)
Screen over stranding
None
Max. conductor temperature
65 °C
Nominal cross section conductor (AWG)
10 kcmil
Outer diameter approx.
14 mm
Shape of conductor
Round
Drain wire
FALSE
Screen over stranding element
None
Conductor material
Copper
Max. tensile strength during installation
-
Nominal cross section conductor
1.5 mm²
Material core insulation
Polyamide (PA)
Screen
FALSE
Nominal voltage U0
250 V
AWG size
Other
Core identification according to HD 308 S2
FALSE
Flame retardant according to IEC 60332-1-2
TRUE
Flame retardant according to IEC 60332-3-22 (Cat A)
FALSE
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
TRUE
Flame retardant according to IEC 60332-3-24 (Cat C)
TRUE
Flame retardant according to IEC 60332-3-23 (Cat B)
TRUE
Halogen free according to EN IEC 60754-1
TRUE
Flame retardant according to IEC 60332-3-25 (Cat D)
TRUE
Number of cores
3
Core identification
Colour
Suspension element
Other
Conductor category
Class 5 = flexible
Nominal cross section pilot/reduced conductors (AWG)
-
Cable geometry
Round
Downloads