Technical Data
Main Features
Input current at signal 1
5 mA
Type of electric connection
Other
Output current
-
Short-circuit protection, outputs available
FALSE
Voltage type (supply voltage)
DC
SIL according to IEC 61508
None
Digital inputs configurable
FALSE
Type of digital output
None
Digital outputs configurable
FALSE
Appendant operation agent (Ex ia)
FALSE
Performance level according to EN ISO 13849-1
None
Permitted voltage at output
Permitted voltage at input
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Type of voltage (input voltage)
AC/DC
Height
90 mm
Time delay at signal change
Appendant operation agent (Ex ib)
FALSE
Type of output voltage
-
Width
33.5 mm
Suitable for safety functions
FALSE
Redundancy
FALSE
Number of digital outputs
0
Number of digital inputs
32
Supply voltage DC
Explosion safety category for dust
None
Depth
81.3 mm
Power consumption
1.1 W
Explosion safety category for gas
None
Downloads

Modicon TM3 - 32 inputs (HE10) 24Vdc
Product details
SKU Code: TM3DI32K
EAN Code: 3606480611414
Minimum order: 1
Good Availability (4 sellers)
Availability
1 In Stock
£182.76
1 In Stock
£230.57
4 In Stock
£273.97
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
1 In Stock | £182.76 Ex. VAT | |
![]() |
1 In Stock | £230.57 Ex. VAT | |
![]() |
4 In Stock | £273.97 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
91 loyalty points
Price Range:
£182.76 > £273.97 ex. vat
Technical Data
Main Features
Input current at signal 1
5 mA
Type of electric connection
Other
Output current
-
Short-circuit protection, outputs available
FALSE
Voltage type (supply voltage)
DC
SIL according to IEC 61508
None
Digital inputs configurable
FALSE
Type of digital output
None
Digital outputs configurable
FALSE
Appendant operation agent (Ex ia)
FALSE
Performance level according to EN ISO 13849-1
None
Permitted voltage at output
Permitted voltage at input
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Type of voltage (input voltage)
AC/DC
Height
90 mm
Time delay at signal change
Appendant operation agent (Ex ib)
FALSE
Type of output voltage
-
Width
33.5 mm
Suitable for safety functions
FALSE
Redundancy
FALSE
Number of digital outputs
0
Number of digital inputs
32
Supply voltage DC
Explosion safety category for dust
None
Depth
81.3 mm
Power consumption
1.1 W
Explosion safety category for gas
None
Downloads