Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

PowerLogic HDPM6000, Base unit calibrated for 60Hz, 480v Zoomed Image
Schneider Electric

PowerLogic HDPM6000, Base unit calibrated for 60Hz, 480v

This is an integrated solution for monitoring multi-circuits and power quality by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres, facilities and energy management in buildings. Allow monitoring of loads up to 4000A with utility grade accuracy on all branch channels. The head unit measure the voltage reference and aggregate data from the connected elements. Allow measurement of energy, power demand, instantaneous power, current, harmonic, voltage and more - in total or per phases. Devices can be connected in dasy-chain thanks to CAT5 or CAT6 straight-through Ethernet cable. The HDPM6000 series can also maintain multiple, concurrent sessions with EPMS, DCIM or BMS applications via the Modbus, SNMP and BACnet IP protocols. The unit need to be supplied in 24VDC, an adaptator is available to convert 480VAC (264V to 575VAC) network to needed voltage. Input reference voltage can be configured between 120 to 480VAC, frequency is calibrated for 50 or 60Hz. The head unit dimensions are 222mm in width, 51mm in height and 122mm in depth connector included. The elements can be mounted on a DIN rail thanks to the clips at the back side. Could be associated with a touchscreen display, that could provide information from up to 4 head units. Integration of EcoStruxure Power Monitoring Expert and Power Operation features for possible software monitoring. The system PowerLogic HDPM6000 can help you identify increased harmonics in the rack servers to detect a potential disruption. Thanks to daisy-chain, it is possible to connect additional modules if the head unit capacity isn't exceeded.

Product details

SKU Code: METSEHDPM6S480VC

EAN Code: 3606481985880

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

1217 loyalty points

Technical Data

Main Features

Supporting protocol for IEC 60870

FALSE

Supporting protocol for DNP3

FALSE

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

FALSE

Number of HW-interfaces parallel

0

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

SIL according to IEC 61508

None

Number of relay outputs

0

Max. number of time switches

0

With optical interface

FALSE

System accessory

FALSE

Number of HW-interfaces wireless

0

Additional program memory possible

FALSE

Performance level according to EN ISO 13849-1

None

Certified for UL hazardous location division 2

FALSE

Radio standard GPRS

FALSE

Height

51.04 mm

Supporting protocol for INTERBUS-Safety

FALSE

Certified for UL hazardous location class I

FALSE

Certified for UL hazardous location class III

FALSE

Certified for UL hazardous location division 1

FALSE

Certified for UL hazardous location class II

FALSE

Width

221.74 mm

Supporting protocol for EtherCAT

FALSE

Redundancy

FALSE

Supporting protocol for AS-Interface Safety at Work

FALSE

Radio standard GSM

FALSE

Explosion safety category for dust

None

Radio standard UMTS

FALSE

Depth

104.65 mm

Explosion safety category for gas

None

Supporting protocol for DeviceNet Safety

FALSE

Supporting protocol for EtherNet/IP

FALSE

Supporting protocol for Foundation Fieldbus

FALSE

Certified for UL hazardous location group C (ethylene)

FALSE

Certified for UL hazardous location group A (acetylene)

FALSE

Certified for UL hazardous location group B (hydrogen)

FALSE

Certified for UL hazardous location group F (carbonaceous dusts)

FALSE

Certified for UL hazardous location group G (non-conductive dusts)

FALSE

Certified for UL hazardous location group D (propane)

FALSE

Certified for UL hazardous location group E (metal dusts)

FALSE

With display

FALSE

Model

Compact

Supporting protocol for SafetyBUS p

FALSE

Processing time (1K, binary operation)

2000 ms

Voltage type (supply voltage)

DC

Type of memory

Other

Supporting protocol for PROFINET CBA

FALSE

Long-Term Evolution (LTE)

FALSE

Supporting protocol for PROFINET IO

FALSE

Memory size

8 kByte

Supporting protocol for PROFIsafe

FALSE

Radio standard Bluetooth

FALSE

Supporting protocol for ASI

FALSE

Radio standard WLAN 802.11

FALSE

Appendant operation agent (Ex ia)

FALSE

Supporting protocol for PROFIBUS

FALSE

Supply voltage AC 50 Hz

Front built-in possible

FALSE

Supply voltage AC 60 Hz

Supporting protocol for TCP/IP

TRUE

Supporting protocol for KNX

FALSE

Appendant operation agent (Ex ib)

FALSE

Supporting protocol for CAN

FALSE

IO link master

FALSE

Supporting protocol for INTERBUS

FALSE

Supporting protocol for IEC 61850 Ethernet

FALSE

Suitable for rail mounting

FALSE

Supporting protocol for DeviceNet

FALSE

Number of digital outputs

0

Suitable for safety functions

FALSE

Supporting protocol for Modbus

TRUE

Number of digital inputs

0

Supporting protocol for Data-Highway

FALSE

Supply voltage DC

Number of analogue outputs

0

Rack-assembly possible

FALSE

Number of analogue inputs

8

Supporting protocol for LON

FALSE

Supporting protocol for other bus systems

FALSE

Supporting protocol for SUCONET

FALSE

Number of HW-interfaces RS-422

0

Wall mounting/direct mounting

TRUE

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

2

Number of HW-interfaces RS-232

0

Downloads