Technical Data
Main Features
Supporting protocol for IEC 60870
FALSE
Supporting protocol for DNP3
FALSE
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
1
SIL according to IEC 61508
None
Number of relay outputs
0
Max. number of time switches
0
With optical interface
FALSE
System accessory
FALSE
Number of HW-interfaces wireless
0
Additional program memory possible
TRUE
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 2
FALSE
Radio standard GPRS
FALSE
Height
90 mm
Supporting protocol for INTERBUS-Safety
FALSE
Certified for UL hazardous location class I
FALSE
Certified for UL hazardous location class III
FALSE
Certified for UL hazardous location division 1
FALSE
Certified for UL hazardous location class II
FALSE
Width
54 mm
Supporting protocol for EtherCAT
FALSE
Redundancy
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Radio standard GSM
FALSE
Explosion safety category for dust
None
Radio standard UMTS
FALSE
Depth
95 mm
Explosion safety category for gas
None
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for Foundation Fieldbus
FALSE
Certified for UL hazardous location group C (ethylene)
FALSE
Certified for UL hazardous location group A (acetylene)
FALSE
Certified for UL hazardous location group B (hydrogen)
FALSE
Certified for UL hazardous location group F (carbonaceous dusts)
FALSE
Certified for UL hazardous location group G (non-conductive dusts)
FALSE
Certified for UL hazardous location group D (propane)
FALSE
Certified for UL hazardous location group E (metal dusts)
FALSE
With display
FALSE
Model
Modular
Supporting protocol for SafetyBUS p
FALSE
Processing time (1K, binary operation)
0.022 ms
Voltage type (supply voltage)
DC
Type of memory
NVRAM
Supporting protocol for PROFINET CBA
FALSE
Long-Term Evolution (LTE)
FALSE
Supporting protocol for PROFINET IO
FALSE
Memory size
64000 kByte
Supporting protocol for PROFIsafe
FALSE
Radio standard Bluetooth
FALSE
Supporting protocol for ASI
FALSE
Radio standard WLAN 802.11
FALSE
Appendant operation agent (Ex ia)
FALSE
Supporting protocol for PROFIBUS
FALSE
Supply voltage AC 50 Hz
Front built-in possible
FALSE
Supporting protocol for TCP/IP
TRUE
Supply voltage AC 60 Hz
Supporting protocol for KNX
FALSE
Appendant operation agent (Ex ib)
FALSE
Supporting protocol for CAN
FALSE
IO link master
FALSE
Supporting protocol for INTERBUS
FALSE
Supporting protocol for IEC 61850 Ethernet
FALSE
Suitable for rail mounting
TRUE
Supporting protocol for DeviceNet
FALSE
Number of digital outputs
0
Suitable for safety functions
FALSE
Supporting protocol for Modbus
TRUE
Number of digital inputs
0
Supporting protocol for Data-Highway
FALSE
Supply voltage DC
Number of analogue outputs
0
Rack-assembly possible
FALSE
Number of analogue inputs
0
Supporting protocol for LON
FALSE
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Wall mounting/direct mounting
TRUE
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
3
Number of HW-interfaces RS-232
1
Downloads

controller M251 2x Ethernet
Product details
SKU Code: TM251MESE
EAN Code: 3606480648878
Minimum order: 1
Some Availability (2 sellers)
Availability
5 In Stock
£367.01
Out of Stock
£425.40
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
5 In Stock | £367.01 Ex. VAT | |
![]() |
Out of Stock | £425.40 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
172 loyalty points
Price:
£367.01 ex. vat
Technical Data
Main Features
Supporting protocol for IEC 60870
FALSE
Supporting protocol for DNP3
FALSE
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
1
SIL according to IEC 61508
None
Number of relay outputs
0
Max. number of time switches
0
With optical interface
FALSE
System accessory
FALSE
Number of HW-interfaces wireless
0
Additional program memory possible
TRUE
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 2
FALSE
Radio standard GPRS
FALSE
Height
90 mm
Supporting protocol for INTERBUS-Safety
FALSE
Certified for UL hazardous location class I
FALSE
Certified for UL hazardous location class III
FALSE
Certified for UL hazardous location division 1
FALSE
Certified for UL hazardous location class II
FALSE
Width
54 mm
Supporting protocol for EtherCAT
FALSE
Redundancy
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Radio standard GSM
FALSE
Explosion safety category for dust
None
Radio standard UMTS
FALSE
Depth
95 mm
Explosion safety category for gas
None
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for Foundation Fieldbus
FALSE
Certified for UL hazardous location group C (ethylene)
FALSE
Certified for UL hazardous location group A (acetylene)
FALSE
Certified for UL hazardous location group B (hydrogen)
FALSE
Certified for UL hazardous location group F (carbonaceous dusts)
FALSE
Certified for UL hazardous location group G (non-conductive dusts)
FALSE
Certified for UL hazardous location group D (propane)
FALSE
Certified for UL hazardous location group E (metal dusts)
FALSE
With display
FALSE
Model
Modular
Supporting protocol for SafetyBUS p
FALSE
Processing time (1K, binary operation)
0.022 ms
Voltage type (supply voltage)
DC
Type of memory
NVRAM
Supporting protocol for PROFINET CBA
FALSE
Long-Term Evolution (LTE)
FALSE
Supporting protocol for PROFINET IO
FALSE
Memory size
64000 kByte
Supporting protocol for PROFIsafe
FALSE
Radio standard Bluetooth
FALSE
Supporting protocol for ASI
FALSE
Radio standard WLAN 802.11
FALSE
Appendant operation agent (Ex ia)
FALSE
Supporting protocol for PROFIBUS
FALSE
Supply voltage AC 50 Hz
Front built-in possible
FALSE
Supporting protocol for TCP/IP
TRUE
Supply voltage AC 60 Hz
Supporting protocol for KNX
FALSE
Appendant operation agent (Ex ib)
FALSE
Supporting protocol for CAN
FALSE
IO link master
FALSE
Supporting protocol for INTERBUS
FALSE
Supporting protocol for IEC 61850 Ethernet
FALSE
Suitable for rail mounting
TRUE
Supporting protocol for DeviceNet
FALSE
Number of digital outputs
0
Suitable for safety functions
FALSE
Supporting protocol for Modbus
TRUE
Number of digital inputs
0
Supporting protocol for Data-Highway
FALSE
Supply voltage DC
Number of analogue outputs
0
Rack-assembly possible
FALSE
Number of analogue inputs
0
Supporting protocol for LON
FALSE
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Wall mounting/direct mounting
TRUE
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
3
Number of HW-interfaces RS-232
1
Downloads