Controller M241 24 IO transistor PNP Ethernet CAN master

Controller M241 24 IO transistor PNP Ethernet CAN master

This TM241 controller is part of the Modicon M241 Logic controller range. It has 24 logic I/O and it is supplied with 24V dc. It is supplied with removable screw terminal blocks for connecting the I/O, a removable terminal block for connecting the power supply, a button cell backup battery BR2032. This M241 logic controller has 5 embedded communication ports, two serial links (RS232/RS485 and RS485) and USB mini-B programming port. It also has an Ethernet port and a CANopen port. It enables the control of simple movements or of control loops. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.

Product identifiers

SKU: TM241CEC24T
EAN: 3606480611117
GTIN: 3606480611117
MPN: TM241CEC24T

V+ Loyalty points:

208

Price range: £ 443.84 - £ 527.38 Excl. VAT


Categories

Features

Depth
95 mm
Model
Compact
Width
150 mm
Height
90 mm
Redundancy
FALSE
Memory size
64000 kByte
With display
FALSE
IO link master
FALSE
Type of memory
NVRAM
System accessory
FALSE
Supply voltage DC
Radio standard GSM
FALSE
Radio standard GPRS
FALSE
Radio standard UMTS
FALSE
Rack-assembly possible
FALSE
With optical interface
FALSE
Front built-in possible
FALSE
Number of relay outputs
0
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
14
Radio standard Bluetooth
FALSE
Long-Term Evolution (LTE)
FALSE
Number of analogue inputs
0
Number of digital outputs
10
Number of analogue outputs
0
Radio standard WLAN 802.11
FALSE
SIL according to IEC 61508
None
Suitable for rail mounting
TRUE
Number of HW-interfaces USB
1
Supporting protocol for ASI
FALSE
Supporting protocol for CAN
TRUE
Supporting protocol for KNX
FALSE
Supporting protocol for LON
FALSE
Max. number of time switches
0
Supporting protocol for DNP3
FALSE
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
FALSE
Voltage type (supply voltage)
DC
Wall mounting/direct mounting
TRUE
Number of HW-interfaces RS-232
2
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
2
Supporting protocol for Modbus
TRUE
Supporting protocol for SERCOS
FALSE
Supporting protocol for TCP/IP
TRUE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
FALSE
Supporting protocol for INTERBUS
FALSE
Supporting protocol for PROFIBUS
FALSE
Appendant operation agent (Ex ia)
FALSE
Appendant operation agent (Ex ib)
FALSE
Explosion safety category for gas
None
Supporting protocol for DeviceNet
FALSE
Supporting protocol for IEC 60870
FALSE
Supporting protocol for PROFIsafe
FALSE
Additional program memory possible
TRUE
Explosion safety category for dust
None
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for Data-Highway
FALSE
Supporting protocol for PROFINET CBA
FALSE
Processing time (1K, binary operation)
0.022 ms
Supporting protocol for INTERBUS-Safety
FALSE
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for other bus systems
FALSE
Supporting protocol for IEC 61850 Ethernet
FALSE
Certified for UL hazardous location class I
FALSE
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for Foundation Fieldbus
FALSE
Certified for UL hazardous location class II
FALSE
Certified for UL hazardous location class III
FALSE
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
FALSE
Certified for UL hazardous location division 2
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Certified for UL hazardous location group D (propane)
FALSE
Certified for UL hazardous location group B (hydrogen)
FALSE
Certified for UL hazardous location group C (ethylene)
FALSE
Certified for UL hazardous location group A (acetylene)
FALSE
Certified for UL hazardous location group E (metal dusts)
FALSE
Certified for UL hazardous location group F (carbonaceous dusts)
FALSE
Certified for UL hazardous location group G (non-conductive dusts)
FALSE