Technical Data
Main Features
Number of HW-interfaces parallel
0
Supporting protocol for SERCOS
FALSE
Number of interfaces PROFINET
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
1
SIL according to IEC 61508
None
With optical interface
FALSE
Number of HW-interfaces wireless
0
Transmission rate
115.2 kBit/s
With potential separation
FALSE
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 2
FALSE
Radio standard GPRS
FALSE
Height
96.5 mm
Supporting protocol for INTERBUS-Safety
FALSE
Certified for UL hazardous location class I
FALSE
Certified for UL hazardous location class III
FALSE
Certified for UL hazardous location division 1
FALSE
Certified for UL hazardous location class II
FALSE
Width
27 mm
Supporting protocol for EtherCAT
FALSE
Number of HW-interfaces CAN
0
Redundancy
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Explosion safety category for dust
None
Radio standard GSM
FALSE
Radio standard UMTS
FALSE
Depth
70 mm
Explosion safety category for gas
None
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for Foundation Fieldbus
FALSE
Certified for UL hazardous location group C (ethylene)
FALSE
Certified for UL hazardous location group A (acetylene)
FALSE
Certified for UL hazardous location group B (hydrogen)
FALSE
Certified for UL hazardous location group F (carbonaceous dusts)
FALSE
Certified for UL hazardous location group G (non-conductive dusts)
FALSE
Certified for UL hazardous location group D (propane)
FALSE
Certified for UL hazardous location group E (metal dusts)
FALSE
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for PROFIsafe
FALSE
Radio standard Bluetooth
FALSE
Supporting protocol for ASI
FALSE
Radio standard WLAN 802.11
FALSE
Supporting protocol for PROFIBUS
FALSE
Appendant operation agent (Ex ia)
FALSE
Type of data transmission
Other
Supporting protocol for TCP/IP
FALSE
Supporting protocol for KNX
FALSE
Supporting protocol for CAN
FALSE
Appendant operation agent (Ex ib)
FALSE
IO link master
FALSE
Supporting protocol for INTERBUS
FALSE
Supporting protocol for DeviceNet
FALSE
Suitable for safety functions
FALSE
Supporting protocol for Modbus
TRUE
Supporting protocol for Data-Highway
FALSE
Power consumption
19.2 W
Supporting protocol for LON
FALSE
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
0
Downloads

IP20 I/O Distributed Optimized TM3 Bus Coupler Module Serial Line Interface
Product details
SKU Code: TM3BCSL
EAN Code: 3606489811051
Minimum order: 1
This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.
No Availability (0 sellers)
86 loyalty points
Technical Data
Main Features
Number of HW-interfaces parallel
0
Supporting protocol for SERCOS
FALSE
Number of interfaces PROFINET
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
1
SIL according to IEC 61508
None
With optical interface
FALSE
Number of HW-interfaces wireless
0
Transmission rate
115.2 kBit/s
With potential separation
FALSE
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 2
FALSE
Radio standard GPRS
FALSE
Height
96.5 mm
Supporting protocol for INTERBUS-Safety
FALSE
Certified for UL hazardous location class I
FALSE
Certified for UL hazardous location class III
FALSE
Certified for UL hazardous location division 1
FALSE
Certified for UL hazardous location class II
FALSE
Width
27 mm
Supporting protocol for EtherCAT
FALSE
Number of HW-interfaces CAN
0
Redundancy
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Explosion safety category for dust
None
Radio standard GSM
FALSE
Radio standard UMTS
FALSE
Depth
70 mm
Explosion safety category for gas
None
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for Foundation Fieldbus
FALSE
Certified for UL hazardous location group C (ethylene)
FALSE
Certified for UL hazardous location group A (acetylene)
FALSE
Certified for UL hazardous location group B (hydrogen)
FALSE
Certified for UL hazardous location group F (carbonaceous dusts)
FALSE
Certified for UL hazardous location group G (non-conductive dusts)
FALSE
Certified for UL hazardous location group D (propane)
FALSE
Certified for UL hazardous location group E (metal dusts)
FALSE
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for PROFIsafe
FALSE
Radio standard Bluetooth
FALSE
Supporting protocol for ASI
FALSE
Radio standard WLAN 802.11
FALSE
Supporting protocol for PROFIBUS
FALSE
Appendant operation agent (Ex ia)
FALSE
Type of data transmission
Other
Supporting protocol for TCP/IP
FALSE
Supporting protocol for KNX
FALSE
Supporting protocol for CAN
FALSE
Appendant operation agent (Ex ib)
FALSE
IO link master
FALSE
Supporting protocol for INTERBUS
FALSE
Supporting protocol for DeviceNet
FALSE
Suitable for safety functions
FALSE
Supporting protocol for Modbus
TRUE
Supporting protocol for Data-Highway
FALSE
Power consumption
19.2 W
Supporting protocol for LON
FALSE
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
0
Downloads