Thermal magnetic circuit breaker, TeSys GB2, 2P, 10 A, Icu 1.5 kA@415 V Zoomed Image
Schneider Electric

Thermal magnetic circuit breaker, TeSys GB2, 2P, 10 A, Icu 1.5 kA@415 V

TeSys GB circuit breaker, 2 poles (2P), 10A/415V, for the protection of industrial equipment control circuits. It provides thermal magnetic protection with a magnetic tripping level at 138A (13 In) and breaking capacity Icu 1.5kA@415V. It can also be used for protection of DC loads up to 10A/24V DC-13 with a breaking capacity Icu 1.5kA@24V. Compact device (30mm wide), mounting on 35mm DIN-rail, control by toggle lever (start-stop guaranteed for 8000 cycles). Sold in lots of 3 units. It conforms to IEC 60947-1 and IEC 60947-2.

Product details

SKU Code: GB2DB16

EAN Code: 3389110865516

Minimum order: 1

Some Availability (3 sellers)

Availability

BPX Electro Mechanical

3 In Stock

£40.60

Control Components Anglia

Back Order Call for availability on 0345 030 60 80

£62.94

Farnell

Back Order Manufacturer lead time of 5 weeks.

£171.66

(unit price £57.22) Selling in packs of 3.

Distributor Availability Price  
BPX Electro Mechanical 3 In Stock £40.60 Ex. VAT
Control Components Anglia Back Order Call for availability on 0345 030 60 80 £62.94 Ex. VAT
Farnell Back Order Manufacturer lead time of 5 weeks. £171.66 Ex. VAT (unit price £57.22) Selling in packs of 3.

21 loyalty points

Price Range:

£40.60 > £171.66 ex. vat

Technical Data

Main Features

Frequency

Built-in depth

78 mm

Width in number of modular spacings

2

Number of poles (total)

2

Rated insulation voltage Ui

415 V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5 kA

Additional equipment possible

FALSE

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-

Rated impulse withstand voltage Uimp

4 kV

Degree of protection (IP)

IP20

Rated current

10 A

Rated voltage

415 V

Release characteristic

Other

Concurrently switching neutral conductor

FALSE

Flush-mounted installation

FALSE

Voltage type

AC

Explosion-proof

FALSE

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5 kA

Connectable conductor cross section solid-core

Over voltage category

3

Current limiting class

3

Ambient temperature during operating

Connectable conductor cross section multi-wired

Pollution degree

2

Power loss

-