Technical Data
Main Features
Frequency
Built-in depth
78 mm
Width in number of modular spacings
2
Number of poles (total)
2
Rated insulation voltage Ui
415 V
Number of protected poles
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
1.5 kA
Additional equipment possible
FALSE
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
4 kV
Degree of protection (IP)
IP20
Rated current
10 A
Rated voltage
415 V
Release characteristic
Other
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC
Explosion-proof
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
1.5 kA
Connectable conductor cross section solid-core
Over voltage category
3
Current limiting class
3
Ambient temperature during operating
Connectable conductor cross section multi-wired
Pollution degree
2
Power loss
-
Downloads

Thermal magnetic circuit breaker, TeSys GB2, 2P, 10 A, Icu 1.5 kA@415 V
Product details
SKU Code: GB2DB16
EAN Code: 3389110865516
Minimum order: 1
Some Availability (3 sellers)
Availability
3 In Stock
£40.60
Back Order Call for availability on 0345 030 60 80
£62.94
Back Order Manufacturer lead time of 5 weeks.
£171.66
(unit price £57.22) Selling in packs of 3.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
3 In Stock | £40.60 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £62.94 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £171.66 Ex. VAT | (unit price £57.22) Selling in packs of 3. |
21 loyalty points
Price Range:
£40.60 > £171.66 ex. vat
Technical Data
Main Features
Frequency
Built-in depth
78 mm
Width in number of modular spacings
2
Number of poles (total)
2
Rated insulation voltage Ui
415 V
Number of protected poles
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
1.5 kA
Additional equipment possible
FALSE
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
4 kV
Degree of protection (IP)
IP20
Rated current
10 A
Rated voltage
415 V
Release characteristic
Other
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC
Explosion-proof
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
1.5 kA
Connectable conductor cross section solid-core
Over voltage category
3
Current limiting class
3
Ambient temperature during operating
Connectable conductor cross section multi-wired
Pollution degree
2
Power loss
-
Downloads