Technical Data
Main Features
Frequency
Built-in depth
74 mm
Width in number of modular spacings
1
Rated insulation voltage Ui
250 V
Number of poles (total)
1
Number of protected poles
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Additional equipment possible
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
1.5 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
4 kV
Degree of protection (IP)
IP20
Rated current
12 A
Rated voltage
250 V
Release characteristic
Other
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
-
Over voltage category
3
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
2
Power loss
-
Downloads

Thermal magnetic circuit breaker, TeSys GB2, 1P, 12 A, Icu 1.5 kA@240 V
Product details
SKU Code: GB2CB20
EAN Code: 3389110214659
Minimum order: 1
Some Availability (3 sellers)
Availability
10 In Stock
£17.53
Back Order Call for availability on 0345 030 60 80
£27.18
Out of Stock
£24.71
Back Order Manufacturer lead time of 5 weeks.
£148.26
(unit price £24.71) Selling in packs of 6.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
10 In Stock | £17.53 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £27.18 Ex. VAT | |
![]() |
Out of Stock | £24.71 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £148.26 Ex. VAT | (unit price £24.71) Selling in packs of 6. |
27 loyalty points
Price Range:
£17.53 > £148.26 ex. vat
Technical Data
Main Features
Frequency
Built-in depth
74 mm
Width in number of modular spacings
1
Rated insulation voltage Ui
250 V
Number of poles (total)
1
Number of protected poles
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Additional equipment possible
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
1.5 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
4 kV
Degree of protection (IP)
IP20
Rated current
12 A
Rated voltage
250 V
Release characteristic
Other
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
-
Over voltage category
3
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
2
Power loss
-
Downloads