Technical Data
Main Features
Built-in depth
44 mm
Frequency
Number of poles (total)
2
Width in number of modular spacings
4
Rated insulation voltage Ui
500 V
Number of protected poles
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
20 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
10 A
Rated voltage
277 V
Release characteristic
C
Concurrently switching neutral conductor
TRUE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
10 kA
Connectable conductor cross section solid-core
Over voltage category
4
Ambient temperature during operating
Current limiting class
-
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
1.9 W
Downloads

Multi9 - C60SP - MCB - 2P - 10 A - C Curve - 480Y/277 V - 10 kA - UL 1077
Product details
SKU Code: M9F22210
EAN Code: 3606481168382
Minimum order: 1
Available for Back Order (2 sellers)
Availability
Out of Stock
£38.22
Back Order Call for availability on 0345 030 60 80
£76.45
Out of Stock
£73.58
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £38.22 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £76.45 Ex. VAT | |
![]() |
Out of Stock | £73.58 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
29 loyalty points
Price:
£76.45 ex. vat
Technical Data
Main Features
Built-in depth
44 mm
Frequency
Number of poles (total)
2
Width in number of modular spacings
4
Rated insulation voltage Ui
500 V
Number of protected poles
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
20 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
10 A
Rated voltage
277 V
Release characteristic
C
Concurrently switching neutral conductor
TRUE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
10 kA
Connectable conductor cross section solid-core
Over voltage category
4
Ambient temperature during operating
Current limiting class
-
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
1.9 W
Downloads