Technical Data
Main Features
Built-in depth
44 mm
Frequency
Width in number of modular spacings
2
Rated insulation voltage Ui
500 V
Number of poles (total)
1
Number of protected poles
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
6 A
Rated voltage
277 V
Release characteristic
D
Concurrently switching neutral conductor
TRUE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
3 kA
Connectable conductor cross section solid-core
Over voltage category
4
Current limiting class
-
Ambient temperature during operating
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
1.2 W
Downloads

Multi9 - C60SP - MCB - 1P - 6 A - D Curve - 277 V - 10 kA - UL 1077
Product details
SKU Code: M9F23106
EAN Code: 3606481168832
Minimum order: 1
Some Availability (2 sellers)
Availability
30 In Stock
£15.60
Back Order Call for availability on 0345 030 60 80
£31.20
Out of Stock
£30.03
Distributor | Availability | Price | |
---|---|---|---|
![]() |
30 In Stock | £15.60 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £31.20 Ex. VAT | |
![]() |
Out of Stock | £30.03 Ex. VAT |
12 loyalty points
Price Range:
£15.60 > £31.20 ex. vat
Technical Data
Main Features
Built-in depth
44 mm
Frequency
Width in number of modular spacings
2
Rated insulation voltage Ui
500 V
Number of poles (total)
1
Number of protected poles
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
6 A
Rated voltage
277 V
Release characteristic
D
Concurrently switching neutral conductor
TRUE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
3 kA
Connectable conductor cross section solid-core
Over voltage category
4
Current limiting class
-
Ambient temperature during operating
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
1.2 W
Downloads