Technical Data
Main Features
Frequency
Built-in depth
44 mm
Width in number of modular spacings
1
Rated insulation voltage Ui
500 V
Number of poles (total)
1
Number of protected poles
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
3 A
Rated voltage
240 V
Release characteristic
D
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
-
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
1.9 W
Downloads

Multi9 - C60N - MCB - 1P - 3 A - D Curve - 240 V - 10 kA
Product details
SKU Code: M9F12103
EAN Code: 3606480576607
Minimum order: 1
Some Availability (2 sellers)
Availability
2 In Stock
£18.03
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
2 In Stock | £18.03 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
13 loyalty points
Price:
£18.03 ex. vat
Technical Data
Main Features
Frequency
Built-in depth
44 mm
Width in number of modular spacings
1
Rated insulation voltage Ui
500 V
Number of poles (total)
1
Number of protected poles
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
3 A
Rated voltage
240 V
Release characteristic
D
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
-
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
1.9 W
Downloads