Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Multi9 - C60H-DC - MCB - 2P - 0.5 A - C Curve - 500 V DC - 10 kA Zoomed Image
Schneider Electric

Multi9 - C60H-DC - MCB - 2P - 0.5 A - C Curve - 500 V DC - 10 kA

This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 2P circuit breaker with 2 protected poles, 0.5A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to EN/IEC 60947-2 standard and 20kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.128kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.

Product details

SKU Code: M9U21270

EAN Code: 3606480741722

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

44 loyalty points

Technical Data

Main Features

Built-in depth

44 mm

Frequency

Width in number of modular spacings

2

Rated insulation voltage Ui

500 V

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-

Additional equipment possible

TRUE

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-

Rated impulse withstand voltage Uimp

6 kV

Degree of protection (IP)

IP20

Rated current

0.5 A

Rated voltage

500 V

Release characteristic

C

Concurrently switching neutral conductor

FALSE

Flush-mounted installation

FALSE

Voltage type

DC

Explosion-proof

FALSE

Connectable conductor cross section solid-core

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-

Over voltage category

4

Ambient temperature during operating

Current limiting class

-

Connectable conductor cross section multi-wired

Pollution degree

3

Downloads