Multi 9 - C60BPR - MCB - 2P - 45 A - C Curve - 240 V - 10 kA - UL 489 Zoomed Image
Schneider Electric

Multi 9 - C60BPR - MCB - 2P - 45 A - C Curve - 240 V - 10 kA - UL 489

This Multi9 C60BPR is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 45A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 127mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.

Product details

SKU Code: M9F52245

EAN Code: 3606481170873

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

49 loyalty points

Technical Data

Main Features

Frequency

Built-in depth

48 mm

Rated insulation voltage Ui

500 V

Number of poles (total)

2

Width in number of modular spacings

4

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-

Additional equipment possible

TRUE

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20 kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-

Rated impulse withstand voltage Uimp

6 kV

Degree of protection (IP)

IP20

Rated current

45 A

Rated voltage

240 V

Release characteristic

C

Concurrently switching neutral conductor

TRUE

Voltage type

AC

Flush-mounted installation

FALSE

Explosion-proof

FALSE

Connectable conductor cross section solid-core

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10 kA

Over voltage category

4

Ambient temperature during operating

Current limiting class

-

Connectable conductor cross section multi-wired

Pollution degree

3