Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Miniature circuit-breaker, Acti9 iC60N, 2P, 1 A, C curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2) Zoomed Image
Schneider Electric

Miniature circuit-breaker, Acti9 iC60N, 2P, 1 A, C curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2)

This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 1A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 50kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 0.25kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Product details

SKU Code: A9F74201

EAN Code: 3606480080265

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

21 loyalty points

Technical Data

Main Features

Built-in depth

44.5 mm

Frequency

Number of poles (total)

2

Width in number of modular spacings

2

Rated insulation voltage Ui

500 V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6 kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50 kA

Additional equipment possible

TRUE

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6 kA

Rated impulse withstand voltage Uimp

6 kV

Degree of protection (IP)

IP20

Rated current

1 A

Rated voltage

400 V

Release characteristic

C

Concurrently switching neutral conductor

FALSE

Flush-mounted installation

FALSE

Voltage type

AC/DC

Explosion-proof

FALSE

Connectable conductor cross section solid-core

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50 kA

Over voltage category

4

Current limiting class

3

Ambient temperature during operating

Connectable conductor cross section multi-wired

Pollution degree

3

Power loss

2.3 W