Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

C60PV-DC - 2P - 16A - 800 V - B curve Zoomed Image
Schneider Electric

C60PV-DC - 2P - 16A - 800 V - B curve

This Acti9 C60PV-DC is a low voltage miniature circuit breaker (MCB) dedicated to multi string photovoltaic installations. It is a 2P circuit breaker with 2 protected poles, 16A rated current and B tripping curve. It can be mounted on DIN rail for modular installation. Its width is 8 modules of 9mm. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 1.5kA at 800VDC and 3kA at 650VDC. It is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits. It has an IP40 degree of protection (as per IEC/EN 60529) on its terminals in modular enclosure. Its fast closing mechanism, independent of the speed of actuation of the toggle, improves its service life. The tripping or position indication functions are remotely provided by adding electrical auxiliaries. The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety.

Product details

SKU Code: A9N61651

EAN Code: 3606480504099

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

Technical Data

Main Features

Built-in depth

44 mm

Frequency

Rated insulation voltage Ui

1000 V

Width in number of modular spacings

4

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-

Additional equipment possible

TRUE

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-

Rated impulse withstand voltage Uimp

6 kV

Degree of protection (IP)

Other

Rated current

16 A

Rated voltage

800 V

Release characteristic

B

Concurrently switching neutral conductor

FALSE

Voltage type

DC

Flush-mounted installation

FALSE

Explosion-proof

FALSE

Connectable conductor cross section solid-core

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-

Over voltage category

4

Current limiting class

0

Ambient temperature during operating

Connectable conductor cross section multi-wired

Pollution degree

2

Power loss

10.4 W

Downloads