Technical Data
Main Features
Frequency
Built-in depth
44.5 mm
Width in number of modular spacings
2
Rated insulation voltage Ui
500 V
Number of poles (total)
2
Number of protected poles
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
16 A
Rated voltage
400 V
Release characteristic
D
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
2.4 W
Downloads

Acti9 iC60H 2P 16A D Miniature Circuit Breaker
Product details
SKU Code: A9F55216
EAN Code: 3606480515330
Minimum order: 1
Good Availability (6 sellers)
Availability
Out of Stock
£43.29
19 In Stock
£56.21
33 In Stock
£56.21
11 In Stock
£78.06
2 In Stock
£63.84
Back Order
£75.09
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £43.29 Ex. VAT | |
![]() |
19 In Stock | £56.21 Ex. VAT | |
![]() |
33 In Stock | £56.21 Ex. VAT | |
![]() |
11 In Stock | £78.06 Ex. VAT | |
![]() |
2 In Stock | £63.84 Ex. VAT | |
![]() |
Back Order | £75.09 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
30 loyalty points
Price Range:
£56.21 > £78.06 ex. vat
Technical Data
Main Features
Frequency
Built-in depth
44.5 mm
Width in number of modular spacings
2
Rated insulation voltage Ui
500 V
Number of poles (total)
2
Number of protected poles
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
16 A
Rated voltage
400 V
Release characteristic
D
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
2.4 W
Downloads