Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

temperature transmitter - 0..600 °C/32..112 °F - for thermocouples K Zoomed Image
Schneider Electric

temperature transmitter - 0..600 °C/32..112 °F - for thermocouples K

Product details

SKU Code: RMTK80BD

EAN Code: 3389110109054

Minimum order: 1

Available for Back Order (3 sellers)

Availability

BPX Electro Mechanical

Out of Stock

£124.08

Control Components Anglia

Back Order Call for availability on 0345 030 60 80

£192.37

Farnell

Back Order Manufacturer lead time of 5 weeks.

£189.52

RS Components

Out of Stock

£189.52

Rexel

We currently do not have any data on product availability.

Please visit the partner's website for pricing information.

Distributor Availability Price  
BPX Electro Mechanical Out of Stock £124.08 Ex. VAT
Control Components Anglia Back Order Call for availability on 0345 030 60 80 £192.37 Ex. VAT
Farnell Back Order Manufacturer lead time of 5 weeks. £189.52 Ex. VAT
RS Components Out of Stock £189.52 Ex. VAT
Rexel We currently do not have any data on product availability. Please visit the partner's website for pricing information.

79 loyalty points

Price Range:

£189.52 > £192.37 ex. vat

Technical Data

Main Features

Number of input ranges 0 V ... 24 V

0

Number of input ranges 0 mV ... 200 mV

0

Temperature drift

-

Number of input ranges 0 V ... 20 V

0

Number of input ranges 0 mA ... 20 mA

0

SIL according to IEC 61508

None

Inherently safe according to EN 60947-5-6 NAMUR

FALSE

Rated supply voltage AC

Height

78 mm

Rated supply voltage DC

Depth

80 mm

Number of input ranges 20 mA ... 0 mA

0

Number of input ranges -20 V ... +20 V

0

Number of input ranges -20 mA ... +20 mA

0

Number of input ranges -2.5 V ... +2.5 V

0

Number of input ranges 20 mA ... 4 mA

0

Number of output ranges 5 V ... 0 V

0

Number of input ranges 10 V ... 0 V

0

Number of output ranges -5 V ... +5 V

0

Number of output ranges -5 mA ... +5 mA

0

Number of output ranges 4 mA ... 20 mA

1

Number of input ranges 2 V ... 10 V

0

Number of input ranges -2 V ... +2 V

0

Type of power supply

Active

Number of input ranges -100 mV ... +100 mV

0

Number of output ranges -500 mV ... +500 mV

0

Number of output ranges 5 V ... 1 V

0

Number of channels

1

Number of input ranges 10 V ... 2 V

0

Number of output ranges -60 mV ... +60 mV

0

Number of input ranges -60 mV ... +60 mV

0

Number of input ranges -500 mV ... +500 mV

0

Number of input ranges 4 mA ... 20 mA

0

Number of input ranges +10 V ... -10 V

0

Number of input ranges -300 mV ... +300 mV

0

Number of input ranges 5 V ... 1 V

0

Number of input ranges 5 V ... 0 V

0

Number of input ranges -5 V ... +5 V

0

Number of input ranges +5 V ... -5 V

0

Number of input ranges -5 mA ... +5 mA

0

Number of input ranges 0 mA ... 10 mA

0

Galvanic separation between output to output

FALSE

Number of input ranges 0 V ... 1 V

0

Galvanic separation between input and output

FALSE

Galvanic separation between inputs

FALSE

Galvanic separation between supply voltage and all other current circuits

FALSE

Number of input ranges 0 V ... 2.5 V

0

Number of input ranges 0 V ... 2 V

0

Number of input ranges 0 mV ... 100 mV

0

Number of input ranges 0 V ... 10 V

0

Number of output ranges 0 mA ... 5 mA

0

Switching frequency

100 Hz

Number of output ranges 0 mV ... 300 mV

0

Number of output ranges 0 V ... 30 V

0

Number of output ranges 0 V ... 24 V

0

Switching voltage

10 V

Number of output ranges -1 V ... +1 V

0

Number of output ranges 0 mV ... 60 mV

0

Number of output ranges 0 mV ... 500 mV

0

Number of output ranges 0 V ... 5 V

0

Number of output ranges -10 V ... +10 V

0

Number of output ranges -10 mA ... +10 mA

0

Number of output ranges 1 V ... 5 V

0

Construction type of device

Other

Number of input ranges 1 V ... 5 V

0

Width

25 mm

Number of input ranges -1 V ... +1 V

0

Number of input ranges 0 mV ... 60 mV

0

Number of input ranges 0 mV ... 500 mV

0

Number of input ranges -10 V ... +10 V

0

Number of input ranges -10 mA ... +10 mA

0

Number of output ranges -2 V ... +2 V

0

Number of output ranges -100 mV ... +100 mV

0

Number of output ranges 10 V ... 2 V

0

Number of output ranges 10 V ... 0 V

0

Mounting method

Snap mounting support rail

Number of input ranges 0 V ... 5 V

0

Number of output ranges -20 mA ... +20 mA

0

Number of input ranges 0 mA ... 5 mA

0

Number of output ranges -2.5 V ... +2.5 V

0

Number of input ranges 0 mV ... 300 mV

0

Number of output ranges 2 V ... 10 V

0

Number of input ranges 0 V ... 30 V

0

Number of output ranges -300 mV ... +300 mV

0

Number of output ranges 20 mA ... 4 mA

0

Operating temperature

Number of output ranges 20 mA ... 0 mA

0

Number of output ranges -20 V ... +20 V

0

Type of electric connection

Spring clamp connection

Malfunction message output

FALSE

Load influence

-

Degree of protection (IP)

IP20

Load

Number of output ranges 0 mA ... 20 mA

1

Number of output ranges 0 mA ... 10 mA

0

Number of output ranges 0 V ... 1 V

0

Switching current

-

Number of output ranges +5 V ... -5 V

0

Number of output ranges +10 V ... -10 V

0

Switching power

-

Number of output ranges 0 V ... 2.5 V

0

Number of output ranges 0 V ... 2 V

0

Number of output ranges 0 mV ... 100 mV

0

Power consumption

-

Number of output ranges 0 V ... 10 V

1

Rated operating frequency

Number of output ranges 0 mV ... 200 mV

0

Number of output ranges 0 V ... 20 V

0

Downloads