Technical Data
Main Features
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Type of converter
U converter
With optical interface
FALSE
Mains voltage
Max. output frequency
500 Hz
Height
678 mm
Mains frequency
50/60 Hz
Supporting protocol for INTERBUS-Safety
FALSE
Width
264 mm
With control element
TRUE
With PC connection
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
330 mm
Supporting protocol for DeviceNet Safety
FALSE
Max. output at quadratic load at rated output voltage
18.5 kW
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
18.5 kW
Number of phases output
3
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
TRUE
Supporting protocol for PROFIsafe
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for ASI
FALSE
Supporting protocol for PROFIBUS
TRUE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for TCP/IP
FALSE
Application in domestic- and commercial area permitted
TRUE
Supporting protocol for KNX
FALSE
Degree of protection (IP)
IP55
Supporting protocol for CAN
TRUE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
TRUE
Number of digital outputs
1
Supporting protocol for Modbus
FALSE
Number of digital inputs
8
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
2
4-quadrant operation possible
TRUE
Number of analogue inputs
3
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
TRUE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
3
Nominal output current I2N
39.2 A
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
-
Max. output voltage
480 V
Downloads

variable speed drive, ATV950, 18,5kW, 400/480V, w braking unit/switch, IP55
Product details
SKU Code: ATV950D18N4E
EAN Code: 3606480883996
Minimum order: 1
Available for Back Order (3 sellers)
Availability
Out of Stock
£3,069.18
Back Order Manufacturer lead time of 5 weeks.
£3,820.00
Back Order
£3,820.24
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £3,069.18 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £3,820.00 Ex. VAT | |
![]() |
Back Order | £3,820.24 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
1575 loyalty points
Price Range:
£3,820.00 > £3,820.24 ex. vat
Technical Data
Main Features
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Type of converter
U converter
With optical interface
FALSE
Mains voltage
Max. output frequency
500 Hz
Height
678 mm
Mains frequency
50/60 Hz
Supporting protocol for INTERBUS-Safety
FALSE
Width
264 mm
With control element
TRUE
With PC connection
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
330 mm
Supporting protocol for DeviceNet Safety
FALSE
Max. output at quadratic load at rated output voltage
18.5 kW
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
18.5 kW
Number of phases output
3
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
TRUE
Supporting protocol for PROFIsafe
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for ASI
FALSE
Supporting protocol for PROFIBUS
TRUE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for TCP/IP
FALSE
Application in domestic- and commercial area permitted
TRUE
Supporting protocol for KNX
FALSE
Degree of protection (IP)
IP55
Supporting protocol for CAN
TRUE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
TRUE
Number of digital outputs
1
Supporting protocol for Modbus
FALSE
Number of digital inputs
8
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
2
4-quadrant operation possible
TRUE
Number of analogue inputs
3
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
TRUE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
3
Nominal output current I2N
39.2 A
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
-
Max. output voltage
480 V