Technical Data
Main Features
Supporting protocol for SERCOS
FALSE
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
With optical interface
FALSE
Type of converter
U converter
Mains voltage
Max. output frequency
599 Hz
Height
143 mm
Supporting protocol for INTERBUS-Safety
FALSE
Mains frequency
50/60 Hz
Width
105 mm
With control element
TRUE
With PC connection
TRUE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
138 mm
Max. output at quadratic load at rated output voltage
2.2 kW
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
2.2 kW
Number of phases output
3
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
TRUE
Supporting protocol for PROFIsafe
FALSE
Supporting protocol for ASI
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for PROFIBUS
TRUE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for TCP/IP
TRUE
Supporting protocol for KNX
FALSE
Application in domestic- and commercial area permitted
FALSE
Degree of protection (IP)
IP20
Supporting protocol for CAN
TRUE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
TRUE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
TRUE
Number of digital outputs
1
Supporting protocol for Modbus
TRUE
Number of digital inputs
6
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
1
Number of analogue inputs
3
4-quadrant operation possible
TRUE
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
TRUE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Nominal output current I2N
11 A
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
1
Max. output voltage
240 V
Downloads

variable speed drive, ATV320, 2.2 kW, 200…240 V, 3 phases, compact
Product details
SKU Code: ATV320U22M3C
EAN Code: 3606480966644
Minimum order: 1
Available for Back Order (1 seller)
Availability
Out of Stock
£478.27
Back Order Manufacturer lead time of 5 weeks.
£613.16
Out of Stock
£613.16
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £478.27 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £613.16 Ex. VAT | |
![]() |
Out of Stock | £613.16 Ex. VAT |
253 loyalty points
Price:
£613.16 ex. vat
Technical Data
Main Features
Supporting protocol for SERCOS
FALSE
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
With optical interface
FALSE
Type of converter
U converter
Mains voltage
Max. output frequency
599 Hz
Height
143 mm
Supporting protocol for INTERBUS-Safety
FALSE
Mains frequency
50/60 Hz
Width
105 mm
With control element
TRUE
With PC connection
TRUE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
138 mm
Max. output at quadratic load at rated output voltage
2.2 kW
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
TRUE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
2.2 kW
Number of phases output
3
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
TRUE
Supporting protocol for PROFIsafe
FALSE
Supporting protocol for ASI
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for PROFIBUS
TRUE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for TCP/IP
TRUE
Supporting protocol for KNX
FALSE
Application in domestic- and commercial area permitted
FALSE
Degree of protection (IP)
IP20
Supporting protocol for CAN
TRUE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
TRUE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
TRUE
Number of digital outputs
1
Supporting protocol for Modbus
TRUE
Number of digital inputs
6
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
1
Number of analogue inputs
3
4-quadrant operation possible
TRUE
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
TRUE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Nominal output current I2N
11 A
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
1
Max. output voltage
240 V
Downloads