Technical Data
Main Features
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces other
8
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Type of converter
U converter
With optical interface
FALSE
Mains voltage
Max. output frequency
400 Hz
Height
143 mm
Mains frequency
50/60 Hz
Supporting protocol for INTERBUS-Safety
FALSE
Width
105 mm
With control element
TRUE
With PC connection
TRUE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
131.2 mm
Supporting protocol for DeviceNet Safety
FALSE
Max. output at quadratic load at rated output voltage
2.2 kW
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
2.2 kW
Number of phases output
3
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for PROFIsafe
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for ASI
FALSE
Supporting protocol for PROFIBUS
FALSE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for TCP/IP
FALSE
Application in domestic- and commercial area permitted
TRUE
Supporting protocol for KNX
FALSE
Degree of protection (IP)
IP20
Supporting protocol for CAN
FALSE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
FALSE
Number of digital outputs
1
Supporting protocol for Modbus
TRUE
Number of digital inputs
4
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
1
4-quadrant operation possible
FALSE
Number of analogue inputs
1
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Nominal output current I2N
10 A
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
-
Max. output voltage
230 V
Downloads

variable speed drive ATV12 - 2.2kW - 3hp - 200..240V - 3ph - with heat sink
Product details
SKU Code: ATV12HU22M3
EAN Code: 3606480071188
Minimum order: 1
Available for Back Order (2 sellers)
Availability
Out of Stock
£313.91
Back Order Call for availability on 0345 030 60 80
£402.45
Out of Stock
£390.73
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £313.91 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £402.45 Ex. VAT | |
![]() |
Out of Stock | £390.73 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
161 loyalty points
Price:
£402.45 ex. vat
Technical Data
Main Features
Number of interfaces PROFINET
0
Supporting protocol for SERCOS
FALSE
Number of HW-interfaces parallel
0
Number of HW-interfaces other
8
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Type of converter
U converter
With optical interface
FALSE
Mains voltage
Max. output frequency
400 Hz
Height
143 mm
Mains frequency
50/60 Hz
Supporting protocol for INTERBUS-Safety
FALSE
Width
105 mm
With control element
TRUE
With PC connection
TRUE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
131.2 mm
Supporting protocol for DeviceNet Safety
FALSE
Max. output at quadratic load at rated output voltage
2.2 kW
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
2.2 kW
Number of phases output
3
Supporting protocol for SafetyBUS p
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for PROFIsafe
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for ASI
FALSE
Supporting protocol for PROFIBUS
FALSE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for TCP/IP
FALSE
Application in domestic- and commercial area permitted
TRUE
Supporting protocol for KNX
FALSE
Degree of protection (IP)
IP20
Supporting protocol for CAN
FALSE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
FALSE
Number of digital outputs
1
Supporting protocol for Modbus
TRUE
Number of digital inputs
4
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
1
4-quadrant operation possible
FALSE
Number of analogue inputs
1
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Nominal output current I2N
10 A
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
-
Max. output voltage
230 V
Downloads