Technical Data
Main Features
Supporting protocol for SERCOS
FALSE
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
With optical interface
FALSE
Type of converter
Other
Mains voltage
Max. output frequency
8 Hz
Height
270 mm
Supporting protocol for INTERBUS-Safety
FALSE
Mains frequency
50/60 Hz
Width
68 mm
With control element
FALSE
With PC connection
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
237 mm
Max. output at quadratic load at rated output voltage
0.4 kW
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
0.4 kW
Supporting protocol for SafetyBUS p
FALSE
Number of phases output
3
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for PROFIsafe
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for ASI
FALSE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for PROFIBUS
FALSE
Supporting protocol for TCP/IP
FALSE
Supporting protocol for KNX
FALSE
Application in domestic- and commercial area permitted
FALSE
Degree of protection (IP)
Other
Supporting protocol for CAN
FALSE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
FALSE
Supporting protocol for Modbus
FALSE
Number of digital outputs
2
Number of digital inputs
6
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
1
Number of analogue inputs
3
4-quadrant operation possible
FALSE
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Nominal output current I2N
1.5 A
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
-
Max. output voltage
480 V
Downloads

Motion servo drive, Lexium 32, three phase supply voltage 208/480 V, 0.4 kW
Product details
SKU Code: LXM32SU60N4
EAN Code: 3606480694813
Minimum order: 1
This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.
No Availability (0 sellers)
394 loyalty points
Technical Data
Main Features
Supporting protocol for SERCOS
FALSE
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
With optical interface
FALSE
Type of converter
Other
Mains voltage
Max. output frequency
8 Hz
Height
270 mm
Supporting protocol for INTERBUS-Safety
FALSE
Mains frequency
50/60 Hz
Width
68 mm
With control element
FALSE
With PC connection
FALSE
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of phases input
3
Depth
237 mm
Max. output at quadratic load at rated output voltage
0.4 kW
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for Foundation Fieldbus
FALSE
Max. output at linear load at rated output voltage
0.4 kW
Supporting protocol for SafetyBUS p
FALSE
Number of phases output
3
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for PROFIsafe
FALSE
Relative symmetric net voltage tolerance
10 %
Supporting protocol for ASI
FALSE
Relative symmetric net frequency tolerance
5 %
Supporting protocol for PROFIBUS
FALSE
Supporting protocol for TCP/IP
FALSE
Supporting protocol for KNX
FALSE
Application in domestic- and commercial area permitted
FALSE
Degree of protection (IP)
Other
Supporting protocol for CAN
FALSE
Supporting protocol for INTERBUS
FALSE
Integrated breaking resistance
FALSE
Application in industrial area permitted
TRUE
Supporting protocol for BACnet
FALSE
Supporting protocol for DeviceNet
FALSE
Supporting protocol for Modbus
FALSE
Number of digital outputs
2
Number of digital inputs
6
Supporting protocol for Data-Highway
FALSE
Number of analogue outputs
1
Number of analogue inputs
3
4-quadrant operation possible
FALSE
Supporting protocol for LON
FALSE
Power consumption
-
Supporting protocol for other bus systems
FALSE
Supporting protocol for SUCONET
FALSE
Number of HW-interfaces RS-422
0
Nominal output current I2N
1.5 A
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Degree of protection (NEMA)
-
Max. output voltage
480 V