motion control stepper motor drive - SD328 - <= 2.5 A

This product is part of the Lexium SD3 and motors an offer of 3-phase stepper drives and stepper motors. The 3-phase stepper motor drive with an integrated CANopen and analogue input Modbus communication interface. High torque is available even at low speeds.  It is a motor drive with a rated supply voltage of 100V to 120V, 200V to 230V, a motor phase current of 2.5A, a nominal power of 270W at 230V and maximum mechanical speed of motor drive is 3000RPM. It is furnished with RJ45 connector for CANopen interface, RJ45 connector for Modbus interface, spring terminal for CANopen interface for electrical connection. It is an IP20 and IP40 rated product. Its dimensions are 72mm (Width) x 140mm (Depth) x 145mm (Height). It weighs 1.1kg. The Lexium SD3 with its excellent constant velocity characteristics is ideal for applications such as printing, paper, packaging, handling, labelling, textile industry, scanning, food and beverages. This product is certified by CUL, TUV, CE and UL. It meets EN/IEC 50178, EN/IEC 61800-3 environment 1, EN/IEC 61800-3 environment 1, EN/IEC 61800-3 and EN/IEC 61800-5-1 standards. The SD3 is an universally applicable stepper motor drive. The package is ready for operation within a very short period of time. Connect the stepper motor to the drive, set the current and step resolution. Stepper drives and stepper motors for motion control.

Product details

SKU Code: SD328AU25S2

EAN Code: 3389119224369

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

409 loyalty points

Technical Data

Main Features

Supporting protocol for SERCOS

FALSE

Number of HW-interfaces parallel

0

Number of interfaces PROFINET

0

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Type of converter

Other

With optical interface

FALSE

Mains voltage

Max. output frequency

200000 Hz

Height

145 mm

Supporting protocol for INTERBUS-Safety

FALSE

Mains frequency

50/60 Hz

Width

72 mm

With control element

TRUE

With PC connection

FALSE

Supporting protocol for AS-Interface Safety at Work

FALSE

Number of phases input

1

Depth

140 mm

Max. output at quadratic load at rated output voltage

0.27 kW

Supporting protocol for DeviceNet Safety

FALSE

Supporting protocol for EtherNet/IP

FALSE

Supporting protocol for Foundation Fieldbus

FALSE

Max. output at linear load at rated output voltage

0.27 kW

Supporting protocol for SafetyBUS p

FALSE

Number of phases output

3

Supporting protocol for PROFINET CBA

FALSE

Supporting protocol for PROFINET IO

FALSE

Supporting protocol for PROFIsafe

FALSE

Relative symmetric net voltage tolerance

10 %

Supporting protocol for ASI

FALSE

Supporting protocol for PROFIBUS

FALSE

Relative symmetric net frequency tolerance

5 %

Supporting protocol for TCP/IP

FALSE

Application in domestic- and commercial area permitted

TRUE

Supporting protocol for KNX

FALSE

Degree of protection (IP)

IP20

Supporting protocol for CAN

TRUE

Supporting protocol for INTERBUS

FALSE

Integrated breaking resistance

FALSE

Application in industrial area permitted

TRUE

Supporting protocol for BACnet

FALSE

Supporting protocol for DeviceNet

FALSE

Number of digital outputs

2

Supporting protocol for Modbus

TRUE

Supporting protocol for Data-Highway

FALSE

Number of digital inputs

6

Number of analogue outputs

1

Number of analogue inputs

3

4-quadrant operation possible

FALSE

Supporting protocol for LON

FALSE

Power consumption

-

Supporting protocol for other bus systems

FALSE

Supporting protocol for SUCONET

FALSE

Number of HW-interfaces RS-422

1

Number of HW-interfaces RS-485

0

Nominal output current I2N

2.5 A

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Degree of protection (NEMA)

-

Max. output voltage

24 V