Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Analog IO module, TeSys island, 2 inputs, 1 output Zoomed Image
Schneider Electric

Analog IO module, TeSys island, 2 inputs, 1 output

TeSys island analog IO module, 2 analog inputs, 1 analog output. Connected to a TPRBC bus coupler it is used for advanced control functions (TeSys avatars). Two analog inputs can be configured for measurement of voltage (-10/+10V, 0/+10V), current (0-20mA, 4-20mA) or temperature probes (Ni, Pt, thermocouples). One analog output can be configured for driving voltage source (-10/+10V, 0/+10V) or current source (0-20mA, 4-20mA). Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Product details

SKU Code: TPRAN2X1

EAN Code: 3606489832902

Minimum order: 1

Available for Back Order (3 sellers)

Availability

BPX Electro Mechanical

Out of Stock

£90.00

RS Components

Back Order

£120.00

Farnell

Back Order Manufacturer lead time of 5 weeks.

£141.18

Rexel

We currently do not have any data on product availability.

Please visit the partner's website for pricing information.

Distributor Availability Price  
BPX Electro Mechanical Out of Stock £90.00 Ex. VAT
RS Components Back Order £120.00 Ex. VAT
Farnell Back Order Manufacturer lead time of 5 weeks. £141.18 Ex. VAT
Rexel We currently do not have any data on product availability. Please visit the partner's website for pricing information.

180 loyalty points

Price Range:

£120.00 > £141.18 ex. vat

Technical Data

Main Features

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

FALSE

Number of HW-interfaces parallel

0

Analogue inputs configurable

TRUE

Number of HW-interfaces other

2

Analogue outputs configurable

TRUE

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

SIL according to IEC 61508

None

System accessory

TRUE

Number of HW-interfaces wireless

0

Performance level according to EN ISO 13849-1

None

Certified for UL hazardous location division 2

FALSE

Radio standard GPRS

FALSE

Fieldbus connection over separate bus coupler possible

TRUE

Height

118 mm

Supporting protocol for INTERBUS-Safety

FALSE

Certified for UL hazardous location class I

FALSE

Certified for UL hazardous location class III

FALSE

Certified for UL hazardous location division 1

FALSE

Certified for UL hazardous location class II

FALSE

Width

25 mm

Supporting protocol for EtherCAT

FALSE

Supporting protocol for AS-Interface Safety at Work

FALSE

Radio standard GSM

FALSE

Explosion safety category for dust

None

Radio standard UMTS

FALSE

Depth

114 mm

Explosion safety category for gas

None

Supporting protocol for DeviceNet Safety

FALSE

Supporting protocol for EtherNet/IP

FALSE

Supporting protocol for Foundation Fieldbus

FALSE

Certified for UL hazardous location group C (ethylene)

FALSE

Certified for UL hazardous location group A (acetylene)

FALSE

Certified for UL hazardous location group B (hydrogen)

FALSE

Certified for UL hazardous location group F (carbonaceous dusts)

FALSE

Certified for UL hazardous location group G (non-conductive dusts)

FALSE

Certified for UL hazardous location group D (propane)

FALSE

Certified for UL hazardous location group E (metal dusts)

FALSE

Input, thermocouple

TRUE

Input signal, configurable

TRUE

Type of electric connection

Plug-in connection

Supporting protocol for SafetyBUS p

FALSE

Voltage type (supply voltage)

DC

Input, resistor

FALSE

Input, resistance thermometer

TRUE

Supporting protocol for PROFINET CBA

FALSE

Supporting protocol for PROFINET IO

FALSE

Input, current

TRUE

Input, voltage

TRUE

Supporting protocol for PROFIsafe

FALSE

Radio standard Bluetooth

FALSE

Supporting protocol for ASI

FALSE

Radio standard WLAN 802.11

FALSE

Appendant operation agent (Ex ia)

FALSE

Supporting protocol for PROFIBUS

FALSE

Supply voltage AC 50 Hz

Front built-in possible

FALSE

Supporting protocol for TCP/IP

FALSE

Supply voltage AC 60 Hz

Supporting protocol for KNX

FALSE

Appendant operation agent (Ex ib)

FALSE

Degree of protection (IP)

IP20

Supporting protocol for CAN

FALSE

IO link master

FALSE

Supporting protocol for INTERBUS

FALSE

Suitable for rail mounting

TRUE

Output, voltage

TRUE

Supporting protocol for DeviceNet

FALSE

Resolution of the analogue outputs

12 Bit

Output signal configurable

TRUE

Suitable for safety functions

FALSE

Supporting protocol for Modbus

FALSE

Resolution of the analogue inputs

16 Bit

Output, current

TRUE

Supporting protocol for Data-Highway

FALSE

Supply voltage DC

Number of analogue outputs

1

Rack-assembly possible

FALSE

Number of analogue inputs

2

Supporting protocol for LON

FALSE

Power consumption

-

Supporting protocol for other bus systems

TRUE

Supporting protocol for SUCONET

FALSE

Number of HW-interfaces RS-422

0

Wall mounting/direct mounting

FALSE

Number of HW-interfaces RS-485

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Degree of protection (NEMA)

-

Downloads