Easy9 RCD with overcurrent protection - 1P + Ns - 50 A - B curve - 6000 A - 30mA
This Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.
Product identifiers
SKU: EZ9D16850
EAN: 3606480570247
GTIN: 3606480570247
MPN: EZ9D16850
Loyalty points: 107
Price range: £ 26.95 - £ 28.84 Excl. VAT
Categories
Features
Frequency
|
50 Hz
|
Power loss
|
-
|
Voltage type
|
AC
|
Rated current
|
50 A
|
Rated voltage
|
230 V
|
Built-in depth
|
50 mm
|
Pollution degree
|
2
|
Rated fault current
|
0.03 A
|
Leakage current type
|
A
|
Over voltage category
|
4
|
Current limiting class
|
3
|
Release characteristic
|
C
|
Surge current capacity
|
0.25 kA
|
Number of poles (total)
|
2
|
With interlocking device
|
FALSE
|
Degree of protection (IP)
|
IP20
|
Number of protected poles
|
1
|
Flush-mounted installation
|
FALSE
|
Rated insulation voltage Ui
|
500 V
|
Disconnection characteristic
|
Undelayed
|
Anti-nuisance tripping version
|
FALSE
|
Width in number of modular spacings
|
1
|
Ambient temperature during operating
|
|
Rated impulse withstand voltage Uimp
|
4 kV
|
Concurrently switching neutral conductor
|
TRUE
|
Connectable conductor cross section solid-core
|
|
Connectable conductor cross section multi-wired
|
|
Rated short-circuit breaking capacity according to EN 61009
|
-
|
Rated short-circuit breaking capacity according to IEC 60947-2
|
-
|
Rated short-circuit breaking capacity Icn according to EN 61009-1
|
6 kA
|