Technical Data
Main Features
Built-in depth
50 mm
Width in number of modular spacings
1
Rated insulation voltage Ui
500 V
Number of poles (total)
2
Rated fault current
0.03 A
Number of protected poles
1
Rated short-circuit breaking capacity according to IEC 60947-2
-
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Rated impulse withstand voltage Uimp
4 kV
Degree of protection (IP)
IP20
Anti-nuisance tripping version
FALSE
Leakage current type
A
Rated current
10 A
Rated voltage
230 V
Release characteristic
C
Concurrently switching neutral conductor
TRUE
Flush-mounted installation
FALSE
Voltage type
AC
Frequency
50 Hz
Surge current capacity
0.25 kA
Connectable conductor cross section solid-core
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Disconnection characteristic
Undelayed
Pollution degree
2
Power loss
-
With interlocking device
FALSE
Rated short-circuit breaking capacity according to EN 61009
-
Downloads

Easy9 RCD with overcurrent protection - 1P + Ns - 10 A - B curve - 6000 A - 30mA
Product details
SKU Code: EZ9D16810
EAN Code: 3606480570186
Minimum order: 1
Availability Unknown (1 seller)
Availability
Out of Stock
£28.55
Out of Stock
£28.55
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £28.55 Ex. VAT | |
![]() |
Out of Stock | £28.55 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
107 loyalty points
Price:
Please visit the partner's website for pricing information.
Technical Data
Main Features
Built-in depth
50 mm
Width in number of modular spacings
1
Rated insulation voltage Ui
500 V
Number of poles (total)
2
Rated fault current
0.03 A
Number of protected poles
1
Rated short-circuit breaking capacity according to IEC 60947-2
-
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Rated impulse withstand voltage Uimp
4 kV
Degree of protection (IP)
IP20
Anti-nuisance tripping version
FALSE
Leakage current type
A
Rated current
10 A
Rated voltage
230 V
Release characteristic
C
Concurrently switching neutral conductor
TRUE
Flush-mounted installation
FALSE
Voltage type
AC
Frequency
50 Hz
Surge current capacity
0.25 kA
Connectable conductor cross section solid-core
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Disconnection characteristic
Undelayed
Pollution degree
2
Power loss
-
With interlocking device
FALSE
Rated short-circuit breaking capacity according to EN 61009
-
Downloads