Acti9 iDPN N Vigi - RCBO - 1P+N - 4A - B Curve - 6000A - 30mA - type AC

This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 4A In rated current and B tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its earth fault indicator on front face allows quick identification of the type of default. The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 125g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.

Product details

SKU Code: A9D55604

EAN Code: 3606480472596

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

78 loyalty points

Technical Data

Main Features

Built-in depth

44 mm

Number of poles (total)

2

Width in number of modular spacings

2

Rated insulation voltage Ui

400 V

Rated fault current

0.03 A

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

-

Rated short-circuit breaking capacity Icn according to EN 61009-1

6 kA

Rated impulse withstand voltage Uimp

4 kV

Degree of protection (IP)

IP20

Leakage current type

AC

Anti-nuisance tripping version

FALSE

Rated current

4 A

Rated voltage

230 V

Release characteristic

B

Concurrently switching neutral conductor

TRUE

Flush-mounted installation

FALSE

Voltage type

AC

Surge current capacity

0.25 kA

Frequency

50 Hz

Connectable conductor cross section solid-core

Over voltage category

3

Ambient temperature during operating

Current limiting class

3

Connectable conductor cross section multi-wired

Disconnection characteristic

Other

Pollution degree

3

Power loss

3 W

With interlocking device

FALSE

Rated short-circuit breaking capacity according to EN 61009

6 kA