This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 16A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its earth fault indicator on front face allows quick identification of the type of default. It has a longer service life thanks to its high limitation and fast closing. It has a test button. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 110VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 125g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.

Product details

SKU Code: A9D01616

EAN Code: 3606480684876

Minimum order: 1

This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.

No Availability (0 sellers)

75 loyalty points

Technical Data

Main Features

Built-in depth

44 mm

Width in number of modular spacings

2

Rated insulation voltage Ui

400 V

Number of poles (total)

2

Rated fault current

0.03 A

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

-

Rated short-circuit breaking capacity Icn according to EN 61009-1

6 kA

Rated impulse withstand voltage Uimp

4 kV

Degree of protection (IP)

IP20

Anti-nuisance tripping version

FALSE

Leakage current type

A

Rated current

16 A

Rated voltage

110 V

Release characteristic

C

Concurrently switching neutral conductor

TRUE

Flush-mounted installation

FALSE

Voltage type

AC

Frequency

50 Hz

Surge current capacity

0.25 kA

Connectable conductor cross section solid-core

Over voltage category

3

Ambient temperature during operating

Current limiting class

3

Connectable conductor cross section multi-wired

Disconnection characteristic

Other

Pollution degree

3

Power loss

4.3 W

With interlocking device

FALSE

Rated short-circuit breaking capacity according to EN 61009

6 kA