This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has spring terminals for fast and reliable wiring of safety circuits.

Product details

SKU Code: TM3SAK6RG

EAN Code: 3606485393049

Minimum order: 1

Available for Back Order (2 sellers)

Availability

BPX Electro Mechanical

Out of Stock

£245.02

Farnell

Back Order Manufacturer lead time of 5 weeks.

£341.97

Rexel

We currently do not have any data on product availability.

Please visit the partner's website for pricing information.

Distributor Availability Price  
BPX Electro Mechanical Out of Stock £245.02 Ex. VAT
Farnell Back Order Manufacturer lead time of 5 weeks. £341.97 Ex. VAT
Rexel We currently do not have any data on product availability. Please visit the partner's website for pricing information.

122 loyalty points

Price:

£341.97 ex. vat

Technical Data

Main Features

Release-delay

Type of control voltage 2

DC

Number of outputs, safety related, delayed, with contact

-

Type of electric connection

Other

Model

Other

Voltage type (supply voltage)

DC

Number of outputs, safety related, undelayed, semiconductors

-

With feedback circuit

FALSE

With approval according to UL

FALSE

Number of outputs, safety related, undelayed, with contact

-

Number of outputs, signalling function, delayed, with contact

-

SIL according to IEC 61508

None

Control voltage 1

Type of control voltage 1

DC

Number of outputs, safety related, delayed, semiconductors

-

Number of outputs, signalling function, undelayed, with contact

-

Control voltage 2

Evaluation inputs

Other

EFDE0031

FALSE

Performance level according to EN ISO 13849-1

None

Stop category according to IEC 60204

Other

Voltage type (operating voltage)

DC

Supply voltage AC 50 Hz

Supply voltage AC 60 Hz

With approval for BG BIA

FALSE

Height

94 mm

Number of outputs, signalling function, undelayed, semiconductors

-

Number of outputs, signalling function, delayed, semiconductors

-

Suitable for monitoring of position switches

FALSE

Suitable for monitoring of tactile sensors

FALSE

Suitable for monitoring of valves

FALSE

Width

43.7 mm

Rated switch current

1.1 A

Suitable for rail mounting

FALSE

Type of safety according to IEC 61496-1

1

Supply voltage DC

Operating voltage AC 50 Hz

Operating voltage AC 60 Hz

Depth

73 mm

Power consumption

1.1 W

Operating voltage DC

Suitable for monitoring of magnetic switches

FALSE

Suitable for monitoring of proximity switches

FALSE

Suitable for monitoring of emergency-stop circuits

FALSE

Suitable for monitoring of optoelectronic protection equipment

FALSE

With muting function

FALSE

With start input

FALSE

With detachable clamps

FALSE