Technical Data
Main Features
Release-delay
Type of control voltage 2
-
Number of outputs, safety related, delayed, with contact
0
Type of electric connection
Screw connection
Model
Expansion device
Voltage type (supply voltage)
DC
Number of outputs, safety related, undelayed, semiconductors
0
With feedback circuit
TRUE
Number of outputs, safety related, undelayed, with contact
0
With approval according to UL
TRUE
SIL according to IEC 61508
3
Number of outputs, signalling function, delayed, with contact
0
Control voltage 1
Number of outputs, safety related, delayed, semiconductors
0
Type of control voltage 1
-
Control voltage 2
Number of outputs, signalling function, undelayed, with contact
0
Evaluation inputs
Other
Stop category according to IEC 60204
0 + 1
EFDE0031
TRUE
Performance level according to EN ISO 13849-1
Level e
Voltage type (operating voltage)
DC
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Height
99 mm
With approval for BG BIA
FALSE
Number of outputs, signalling function, undelayed, semiconductors
0
Number of outputs, signalling function, delayed, semiconductors
0
Suitable for monitoring of position switches
TRUE
Suitable for monitoring of tactile sensors
TRUE
Suitable for monitoring of valves
FALSE
Width
22.5 mm
Rated switch current
-
Suitable for rail mounting
TRUE
Type of safety according to IEC 61496-1
4
Supply voltage DC
Operating voltage AC 50 Hz
Power consumption
1.1 W
Depth
114.5 mm
Operating voltage AC 60 Hz
Operating voltage DC
Suitable for monitoring of magnetic switches
TRUE
Suitable for monitoring of proximity switches
TRUE
Suitable for monitoring of emergency-stop circuits
TRUE
Suitable for monitoring of optoelectronic protection equipment
TRUE
With start input
TRUE
With muting function
TRUE
With detachable clamps
TRUE
Downloads

16 Input expansion module with screw term
Product details
SKU Code: XPSMCMDI1600
EAN Code: 3606480748622
Minimum order: 1
Some Availability (3 sellers)
Availability
3 In Stock
£191.67
Back Order Manufacturer lead time of 5 weeks.
£292.77
Out of Stock
£292.77
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
3 In Stock | £191.67 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £292.77 Ex. VAT | |
![]() |
Out of Stock | £292.77 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
118 loyalty points
Price Range:
£191.67 > £292.77 ex. vat
Technical Data
Main Features
Release-delay
Type of control voltage 2
-
Number of outputs, safety related, delayed, with contact
0
Type of electric connection
Screw connection
Model
Expansion device
Voltage type (supply voltage)
DC
Number of outputs, safety related, undelayed, semiconductors
0
With feedback circuit
TRUE
Number of outputs, safety related, undelayed, with contact
0
With approval according to UL
TRUE
SIL according to IEC 61508
3
Number of outputs, signalling function, delayed, with contact
0
Control voltage 1
Number of outputs, safety related, delayed, semiconductors
0
Type of control voltage 1
-
Control voltage 2
Number of outputs, signalling function, undelayed, with contact
0
Evaluation inputs
Other
Stop category according to IEC 60204
0 + 1
EFDE0031
TRUE
Performance level according to EN ISO 13849-1
Level e
Voltage type (operating voltage)
DC
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Height
99 mm
With approval for BG BIA
FALSE
Number of outputs, signalling function, undelayed, semiconductors
0
Number of outputs, signalling function, delayed, semiconductors
0
Suitable for monitoring of position switches
TRUE
Suitable for monitoring of tactile sensors
TRUE
Suitable for monitoring of valves
FALSE
Width
22.5 mm
Rated switch current
-
Suitable for rail mounting
TRUE
Type of safety according to IEC 61496-1
4
Supply voltage DC
Operating voltage AC 50 Hz
Power consumption
1.1 W
Depth
114.5 mm
Operating voltage AC 60 Hz
Operating voltage DC
Suitable for monitoring of magnetic switches
TRUE
Suitable for monitoring of proximity switches
TRUE
Suitable for monitoring of emergency-stop circuits
TRUE
Suitable for monitoring of optoelectronic protection equipment
TRUE
With start input
TRUE
With muting function
TRUE
With detachable clamps
TRUE